Measurement of Functional Use in Upper Extremity Prosthetic Devices Using Wearable Sensors and Machine Learning. (Record no. 11927)

MARC details
000 -LEADER
fixed length control field 02708nam a22004457a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230601s20232023 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1424-8220
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.3390/s23063111 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code PMC10058354 [pmc]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code s23063111 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 36991822
245 ## - TITLE STATEMENT
Title Measurement of Functional Use in Upper Extremity Prosthetic Devices Using Wearable Sensors and Machine Learning.
251 ## - Source
Source Sensors. 23(6), 2023 Mar 14.
252 ## - Abbreviated Source
Abbreviated source Sensors (Basel). 23(6), 2023 Mar 14.
253 ## - Journal Name
Journal name Sensors (Basel, Switzerland)
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2023 Mar 14
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status epublish
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Medline status MEDLINE
266 ## - Date added to catalog
Date added to catalog 06/01/2023
520 ## - SUMMARY, ETC.
Abstract Trials for therapies after an upper limb amputation (ULA) require a focus on the real-world use of the upper limb prosthesis. In this paper, we extend a novel method for identifying upper extremity functional and nonfunctional use to a new patient population: upper limb amputees. We videotaped five amputees and 10 controls performing a series of minimally structured activities while wearing sensors on both wrists that measured linear acceleration and angular velocity. The video data was annotated to provide ground truth for annotating the sensor data. Two different analysis methods were used: one that used fixed-size data chunks to create features to train a Random Forest classifier and one that used variable-size data chunks. For the amputees, the fixed-size data chunk method yielded good results, with 82.7% median accuracy (range of 79.3-85.8) on the 10-fold cross-validation intra-subject test and 69.8% in the leave-one-out inter-subject test (range of 61.4-72.8). The variable-size data method did not improve classifier accuracy compared to the fixed-size method. Our method shows promise for inexpensive and objective quantification of functional upper extremity (UE) use in amputees and furthers the case for use of this method in assessing the impact of UE rehabilitative treatments.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Artificial Limbs
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Wearable Electronic Devices
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Activities of Daily Living
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Machine Learning
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Upper Extremity/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Indexing Automated
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar National Rehabilitation Network
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Barth, Jessica
Institution Code MNRN
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Dromerick, Alexander W
Institution Code MNRN
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Lum, Peter S
Institution Code MNRN
790 ## - Authors
All authors Barth J, Bochniewicz EM, Dromerick AW, Emmer G, Lum PS
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.3390/s23063111">https://dx.doi.org/10.3390/s23063111</a>
Public note https://dx.doi.org/10.3390/s23063111
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 06/02/2023   36991822 36991822 06/02/2023 06/02/2023 Journal Article

Powered by Koha