MARC details
000 -LEADER |
fixed length control field |
02722nam a22004457a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
170508s20162016 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0032-1052 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
27465189 |
245 ## - TITLE STATEMENT |
Title |
Cadaveric Investigation of Active Finger Range of Motion for Detection of Intratendinous Needle Placement. |
251 ## - Source |
Source |
Plastic & Reconstructive Surgery. 138(2):268e-72e, 2016 Aug |
252 ## - Abbreviated Source |
Abbreviated source |
Plast Reconstr Surg. 138(2):268e-72e, 2016 Aug |
253 ## - Journal Name |
Journal name |
Plastic and reconstructive surgery |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2016 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2017 |
266 ## - Date added to catalog |
Date added to catalog |
2017-05-08 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: The authors' purpose was to determine if investigators can predict whether a needle is within a finger's flexor tendon by postinsertion tactile and visualization evaluation in an active range-of-motion cadaver model. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: Because of poor interobserver agreement, sensitivity, and negative predictive value, we conclude that finger range of motion is not a reliable test to detect intratendinous needle placement in this cadaver model. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: In 48 cadaver fingers, a 25-gauge needle, with a 1-cc syringe attached, was placed into one of three randomly assigned positions at the A2 pulley level: within the flexor digitorum profundus, within the flexor digitorum superficialis, or outside both flexors and the sheath. Each finger was cycled through full active range of motion as three hand surgeons, blinded to each other's responses and needle position, recorded whether they thought the needle was intratendinous. The initial investigator confirmed needle position after each surgeon's assessment. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Active cadaver finger range of motion did not allow surgeons to accurately determine whether a needle was in a flexor tendon. There was no statistically significant agreement among the surgeons about whether the needle was intratendinous. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Finger Joint/pp [Physiopathology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Orthopedic Procedures/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Range of Motion, Articular/ph [Physiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Tendon Injuries/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cadaver |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
ROC Curve |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Tendon Injuries/pp [Physiopathology] |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
Curtis National Hand Center |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Randomized Controlled Trial |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Means, Kenneth R Jr |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Parks, Brent G |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Starr, Harlan M Jr |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Tsai, Michael A |
790 ## - Authors |
All authors |
Means KR Jr, Parks BG, Starr HM Jr, Tsai MA |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1097/PRS.0000000000002370">https://dx.doi.org/10.1097/PRS.0000000000002370</a> |
Public note |
https://dx.doi.org/10.1097/PRS.0000000000002370 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |