Cadaveric Investigation of Active Finger Range of Motion for Detection of Intratendinous Needle Placement. (Record no. 2196)

MARC details
000 -LEADER
fixed length control field 02722nam a22004457a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170508s20162016 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0032-1052
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 27465189
245 ## - TITLE STATEMENT
Title Cadaveric Investigation of Active Finger Range of Motion for Detection of Intratendinous Needle Placement.
251 ## - Source
Source Plastic & Reconstructive Surgery. 138(2):268e-72e, 2016 Aug
252 ## - Abbreviated Source
Abbreviated source Plast Reconstr Surg. 138(2):268e-72e, 2016 Aug
253 ## - Journal Name
Journal name Plastic and reconstructive surgery
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2016
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2017
266 ## - Date added to catalog
Date added to catalog 2017-05-08
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: The authors' purpose was to determine if investigators can predict whether a needle is within a finger's flexor tendon by postinsertion tactile and visualization evaluation in an active range-of-motion cadaver model.
520 ## - SUMMARY, ETC.
Abstract CONCLUSION: Because of poor interobserver agreement, sensitivity, and negative predictive value, we conclude that finger range of motion is not a reliable test to detect intratendinous needle placement in this cadaver model.
520 ## - SUMMARY, ETC.
Abstract METHODS: In 48 cadaver fingers, a 25-gauge needle, with a 1-cc syringe attached, was placed into one of three randomly assigned positions at the A2 pulley level: within the flexor digitorum profundus, within the flexor digitorum superficialis, or outside both flexors and the sheath. Each finger was cycled through full active range of motion as three hand surgeons, blinded to each other's responses and needle position, recorded whether they thought the needle was intratendinous. The initial investigator confirmed needle position after each surgeon's assessment.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Active cadaver finger range of motion did not allow surgeons to accurately determine whether a needle was in a flexor tendon. There was no statistically significant agreement among the surgeons about whether the needle was intratendinous.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Finger Joint/pp [Physiopathology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Orthopedic Procedures/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Range of Motion, Articular/ph [Physiology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Tendon Injuries/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cadaver
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element ROC Curve
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Tendon Injuries/pp [Physiopathology]
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution Curtis National Hand Center
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
657 ## - INDEX TERM--FUNCTION
Medline publication type Randomized Controlled Trial
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Means, Kenneth R Jr
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Parks, Brent G
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Starr, Harlan M Jr
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Tsai, Michael A
790 ## - Authors
All authors Means KR Jr, Parks BG, Starr HM Jr, Tsai MA
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1097/PRS.0000000000002370">https://dx.doi.org/10.1097/PRS.0000000000002370</a>
Public note https://dx.doi.org/10.1097/PRS.0000000000002370
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 05/08/2017   27465189 27465189 05/08/2017 05/08/2017 Journal Article

Powered by Koha