MARC details
000 -LEADER |
fixed length control field |
04116nam a22005057a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
170512s20172017 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0735-1097 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
28473128 |
245 ## - TITLE STATEMENT |
Title |
Transcatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses: PARTNER 2 Valve-in-Valve Registry. |
251 ## - Source |
Source |
Journal of the American College of Cardiology. 69(18):2253-2262, 2017 May 09 |
252 ## - Abbreviated Source |
Abbreviated source |
J Am Coll Cardiol. 69(18):2253-2262, 2017 May 09 |
253 ## - Journal Name |
Journal name |
Journal of the American College of Cardiology |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2017 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2017 |
266 ## - Date added to catalog |
Date added to catalog |
2017-05-24 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1995 - present, Available in print through MWHC library:1999-2007 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Early experience with transcatheter aortic valve replacement (TAVR) within failed bioprosthetic surgical aortic valves has shown that valve-in-valve (VIV) TAVR is a feasible therapeutic option with acceptable acute procedural results. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: In high-risk patients, TAVR for bioprosthetic aortic valve failure is associated with relatively low mortality and complication rates, improved hemodynamics, and excellent functional and quality-of-life outcomes at 1 year. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves [PARTNER II]; NCT01314313). |
520 ## - SUMMARY, ETC. |
Abstract |
Copyright � 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Patients with symptomatic degeneration of surgical aortic bioprostheses at high risk (>50% major morbidity or mortality) for reoperative surgery were prospectively enrolled in the multicenter PARTNER (Placement of Aortic Transcatheter Valves) 2 VIV trial and continued access registries. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: The authors examined 30-day and 1-year outcomes in a large cohort of high-risk patients undergoing VIV TAVR. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Valve-in-valve procedures were performed in 365 patients (96 initial registry, 269 continued access patients). Mean age was 78.9 +/- 10.2 years, and mean Society of Thoracic Surgeons score was 9.1 +/- 4.7%. At 30 days, all-cause mortality was 2.7%, stroke was 2.7%, major vascular complication was 4.1%, conversion to surgery was 0.6%, coronary occlusion was 0.8%, and new pacemaker insertion was 1.9%. One-year all-cause mortality was 12.4%. Mortality fell from the initial registry to the subsequent continued access registry, both at 30 days (8.2% vs. 0.7%, respectively; p = 0.0001) and at 1 year (19.7% vs. 9.8%, respectively; p = 0.006). At 1 year, mean gradient was 17.6 mm Hg, and effective orifice area was 1.16 cm<sup>2</sup>, with greater than mild paravalvular regurgitation of 1.9%. Left ventricular ejection fraction increased (50.6% to 54.2%), and mass index decreased (135.7 to 117.6 g/m<sup>2</sup>), with reductions in both mitral (34.9% vs. 12.7%) and tricuspid (31.8% vs. 21.2%) moderate or severe regurgitation (all p < 0.0001). Kansas City Cardiomyopathy Questionnaire score increased (mean: 43.1 to 77.0) and 6-min walk test distance results increased (mean: 163.6 to 252.3 m; both p < 0.0001). |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Valve |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Bioprosthesis/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Heart Valve Prosthesis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Registries |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Transcatheter Aortic Valve Replacement |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Follow-Up Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prospective Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Failure |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Quality of Life |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Reoperation |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Pichard, Augusto D |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Satler, Lowell F |
790 ## - Authors |
All authors |
Alu MC, Blanke P, Dvir D, Herrmann HC, Kodali SK, Leipsic J, Leon MB, Mack MJ, Makkar R, Miller DC, Pibarot P, Pichard A, Satler LF, Suri RM, Svensson L, Webb JG, White JM |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.jacc.2017.02.057">https://dx.doi.org/10.1016/j.jacc.2017.02.057</a> |
Public note |
https://dx.doi.org/10.1016/j.jacc.2017.02.057 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |