Metal Artifact Reduction Magnetic Resonance Imaging Around Arthroplasty Implants: The Negative Effect of Long Echo Trains on the Implant-Related Artifact. (Record no. 2866)

MARC details
000 -LEADER
fixed length control field 03640nam a22004697a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171206s20172017 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0020-9996
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 28079703
245 ## - TITLE STATEMENT
Title Metal Artifact Reduction Magnetic Resonance Imaging Around Arthroplasty Implants: The Negative Effect of Long Echo Trains on the Implant-Related Artifact.
251 ## - Source
Source Investigative Radiology. 52(5):310-316, 2017 May
252 ## - Abbreviated Source
Abbreviated source Invest Radiol. 52(5):310-316, 2017 May
253 ## - Journal Name
Journal name Investigative radiology
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2017
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2017
266 ## - Date added to catalog
Date added to catalog 2017-12-06
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 1996 - present
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: High receiver BW is the most effective parameter for reduction of arthroplasty implant-induced metal artifact on MRI scans, whereas in contradiction to prevalent notions, long echo trains fail to reduce implant-related metal artifacts, but in fact cause degradation of image quality around the implant with resultant larger appearing total metal artifacts.
520 ## - SUMMARY, ETC.
Abstract MATERIALS AND METHODS: Using a total ankle arthroplasty system implanted into a human cadaver ankle and a clinical 1.5 T MRI system, turbo spin echo (TSE) pulse sequences were acquired with ETL ranging from 3 to 23 and receiver bandwidth (BW) from 100 to 750 Hz/pixel, whereas effective echo time and spatial resolution were controlled. A compressed sensing slice encoding for metal artifact correction TSE prototype pulse sequence was used as reference standard. End points included the total implant-related artifact area and implant-related signal void areas. Two raters evaluated the overall image quality and preference across varying BW and ETL. Two-factor analysis of variance, Friedman test, Kruskal-Wallis test, and Pearson correlation were used. P values of less than 0.05 were considered statistically significant.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: Long echo train length (ETL) is an often recommended but unproven technique to decrease metal artifacts on magnetic resonance imaging (MRI) scans. Therefore, we quantitatively and qualitatively assessed the effects of ETL on metal artifact on MRI scans using a cobalt-chromium-containing arthroplasty implant system.
520 ## - SUMMARY, ETC.
Abstract RESULTS: The total implant-related artifact area ranged from 0.119 for compressed sensing slice encoding for metal artifact correction (BW, 600 Hz/pixel; ETL, 3) to 0.265 for TSE (BW, 100 Hz/pixel; ETL, 23). Longer ETL significantly increases the total implant-related artifact area (P = 0.0004), whereas it decreased with increasing BW (P < 0.0001). Implant-related signal void areas were not significantly affected by larger echo train length, but reduced with higher BW (P < 0.0001). Readers had a significant preference for images with high BW and short ETL (P < 0.0001).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Arthroplasty, Replacement, Ankle
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Artifacts
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Image Processing, Computer-Assisted/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Magnetic Resonance Imaging/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Prostheses and Implants
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Ankle/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cadaver
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Chromium
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cobalt
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Metals
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Union Memorial Hospital
656 ## - INDEX TERM--OCCUPATION
Department Orthopaedic Surgery
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors de Cesar Netto, Cesar
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Schon, Lew C
790 ## - Authors
All authors de Cesar Netto C, Fritz J, Kumar NM, Schon LC
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1097/RLI.0000000000000350">https://dx.doi.org/10.1097/RLI.0000000000000350</a>
Public note https://dx.doi.org/10.1097/RLI.0000000000000350
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 12/06/2017   28079703 28079703 12/06/2017 12/06/2017 Journal Article

Powered by Koha