Latissimus Dorsi and Immediate Fat Transfer (LIFT) for Complete Autologous Breast Reconstruction. (Record no. 3152)

MARC details
000 -LEADER
fixed length control field 02838nam a22003497a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180228s20182018 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 2169-7574
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1097/GOX.0000000000001656 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code PMC5811306 [pmc]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 29464176
245 ## - TITLE STATEMENT
Title Latissimus Dorsi and Immediate Fat Transfer (LIFT) for Complete Autologous Breast Reconstruction.
251 ## - Source
Source Plastic and Reconstructive Surgery - Global Open. 6(1):e1656, 2018 Jan
252 ## - Abbreviated Source
Abbreviated source Plast. reconstr. surg., Glob. open. 6(1):e1656, 2018 Jan
253 ## - Journal Name
Journal name Plastic and reconstructive surgery. Global open
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2018
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2018
266 ## - Date added to catalog
Date added to catalog 2018-02-28
520 ## - SUMMARY, ETC.
Abstract Background: Despite the popularity of latissimus dorsi (LD) flap in breast reconstruction, a breast implant is often necessary to achieve sufficient volume. Prior reports describe fat grafting to the LD flap as a secondary procedure to correct contour deformities and improve volume. Our institution has instituted autologous breast reconstruction with an LD flap and immediate fat transfer (LIFT).
520 ## - SUMMARY, ETC.
Abstract Conclusion: Autologous augmentation of the LD flap with lipotransfer has been used to avoid placement of an implant. We improve the technique by performing lipotransfer during index reconstruction. Furthermore, we perform lipotransfer prior to disorigination of the LD muscle to minimize trauma to the flap and increase the efficiency of fat grafting. Our experience demonstrates that this technique is a viable autologous alternative to microsurgical breast reconstruction.
520 ## - SUMMARY, ETC.
Abstract Methods: A retrospective review of all patients undergoing the LIFT procedure was undertaken. Patient age, total volume of fat transfer, length of follow-up, need for adjuvant therapy, and complications were recorded. The procedure begins with harvest of the LD flap and fat. Prior to disorigination of the latissimus muscle, fat is injected into the flap. Flap harvest is then completed and inset to create a breast mound.
520 ## - SUMMARY, ETC.
Abstract Results: Eighteen patients underwent LIFT procedures over 3 years with an average follow-up of 8.7 months (range, 2-24). Four breasts (22.2%) had previously received adjuvant radiation therapy. The mean total fat grafting volume was 515.5mL (range, 325-730) per breast. The average estimated fat graft take was 66.8% (range, 50-80%). Four patients (22.2%) experienced complications.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN PROCESS -- NOT YET INDEXED
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Washington Hospital Center
656 ## - INDEX TERM--OCCUPATION
Department Surgery/Plastic Surgery
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Economides, James M
790 ## - Authors
All authors Economides JM, Song DH
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1097/GOX.0000000000001656">https://dx.doi.org/10.1097/GOX.0000000000001656</a>
Public note https://dx.doi.org/10.1097/GOX.0000000000001656
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 02/28/2018   29464176 29464176 02/28/2018 02/28/2018 Journal Article

Powered by Koha