MARC details
000 -LEADER |
fixed length control field |
04763nam a22006377a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
180220s20182018 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1936-8798 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.jcin.2017.10.041 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S1936-8798(17)32218-5 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
29397361 |
245 ## - TITLE STATEMENT |
Title |
Neurocognition and Cerebral Lesion Burden in High-Risk Patients Before Undergoing Transcatheter Aortic Valve Replacement: Insights From the SENTINEL Trial. |
251 ## - Source |
Source |
Jacc: Cardiovascular Interventions. 11(4):384-392, 2018 02 26 |
252 ## - Abbreviated Source |
Abbreviated source |
JACC Cardiovasc Interv. 11(4):384-392, 2018 02 26 |
253 ## - Journal Name |
Journal name |
JACC. Cardiovascular interventions |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2018 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2018 |
266 ## - Date added to catalog |
Date added to catalog |
2018-02-20 |
501 ## - WITH NOTE |
Local holdings |
Available online through MWHC library: 2008 - present |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: TAVR studies have not shown a correlation between diffusion-weighted image changes and neurocognition. The authors wanted to determine the extent to which there was already impairment at baseline that correlated with cerebrovascular disease. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: There was a significant proportion of aortic stenosis patients with impaired cognition before TAVR, with a relationship between baseline cognitive function and lesion burden likely attributable to longstanding cerebrovascular disease. These findings underscore the importance of pre-interventional testing and magnetic resonance imaging in any research investigating post-surgical cognitive outcomes in patients with cardiovascular disease. |
520 ## - SUMMARY, ETC. |
Abstract |
Copyright (c) 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: SENTINEL (Cerebral Protection in Transcatheter Aortic Valve Replacement) trial patients had cognitive assessments of attention, processing speed, executive function, and verbal and visual memory. Z-scores were based on normative means and SDs, combined into a primary composite z-score. Brain magnetic resonance images were obtained pre-TAVR on 3-T scanners with a T2 fluid-attenuated inversion recovery (FLAIR) sequence. Scores <=-1.5 SD below the normative mean (7th percentile) were considered impairment. Paired t tests compared within-subject scores, and chi-square goodness-of-fit compared the percentage of subjects below -1.5 SD. Correlation and regression analyses assessed the relationship between neurocognitive z-scores and T2 lesion volume. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: The authors sought to determine baseline neurocognition before transcatheter aortic valve replacement (TAVR) and its correlations with pre-TAVR brain imaging. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Among 234 patients tested, the mean composite z-score was -0.65 SD below the normative mean. Domain scores ranged from -0.15 SD for attention to -1.32 SD for executive function. On the basis of the >=1.5 SD normative reference, there were significantly greater percentages of impaired scores in the composite z-score (13.2%; p = 0.019), executive function (41.9%; p < 0.001), verbal memory (p < 0.001), and visual memory (p < 0.001). The regression model between FLAIR lesion volume and baseline cognition showed statistically significant negative correlations. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Valve Stenosis/co [Complications] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Cerebrovascular Disorders/co [Complications] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Cognition |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Cognition Disorders/co [Complications] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Transcatheter Aortic Valve Replacement |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Age Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve Stenosis/di [Diagnosis] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve Stenosis/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Attention |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cerebrovascular Disorders/di [Diagnosis] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cerebrovascular Disorders/px [Psychology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cognition Disorders/di [Diagnosis] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cognition Disorders/px [Psychology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Executive Function |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Magnetic Resonance Imaging |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Memory |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Neuropsychological Tests |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Transcatheter Aortic Valve Replacement/ae [Adverse Effects] |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar National Rehabilitation Network |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Garmoe, William |
790 ## - Authors |
All authors |
Bender HA, Bormann T, Dwyer MG, Garmoe WS, Ghanem A, Kapadia SR, Kodali S, Kraemer C, Lazar RM, Leon MB, Linke A, Mechanic-Hamilton D, Mehran R, Naugle R, Nazif T, Parhizgar A, Pavol MA, Ravdin LD, Stringer AY, Thone-Otto A, Virmani R, Wertheimer JC, White R, Zivadinov R |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.jcin.2017.10.041">https://dx.doi.org/10.1016/j.jcin.2017.10.041</a> |
Public note |
https://dx.doi.org/10.1016/j.jcin.2017.10.041 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |