One-Year Outcomes with a Self-Expanding, Repositionable Transcatheter Heart Valve in Severe Aortic Stenosis Patients: PORTICO-I. (Record no. 3793)

MARC details
000 -LEADER
fixed length control field 03107nam a22003617a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181010s20182018 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0735-1097
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 30261238
245 ## - TITLE STATEMENT
Title One-Year Outcomes with a Self-Expanding, Repositionable Transcatheter Heart Valve in Severe Aortic Stenosis Patients: PORTICO-I.
251 ## - Source
Source Journal of the American College of Cardiology. 2018 Sep 17
252 ## - Abbreviated Source
Abbreviated source J Am Coll Cardiol. 2018 Sep 17
253 ## - Journal Name
Journal name Journal of the American College of Cardiology
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2018
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2019
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status aheadofprint
266 ## - Date added to catalog
Date added to catalog 2018-10-10
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 1995 - present, Available in print through MWHC library:1999-2007
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: The new self-expanding, repositionable transcatheter heart valve (THV) system was designed for treatment of severe, symptomatic aortic stenosis in patients with high surgical risk.
520 ## - SUMMARY, ETC.
Abstract CONCLUSION: Transcatheter aortic valve replacement with the new THV in patients at increased surgical risk is associated with low 1-year mortality and stroke rates. Favorable hemodynamic results at 1 year are observed with low transvalvular pressure gradient and incidence of significant PVL.
520 ## - SUMMARY, ETC.
Abstract Copyright (c) 2018. Published by Elsevier Inc.
520 ## - SUMMARY, ETC.
Abstract METHODS: This ongoing, international, multicenter study evaluated patients with severe, symptomatic aortic stenosis implanted with the THV via transfemoral access and follow-up at 30 days, 1 year and annually through 5 years. The primary endpoint is all-cause mortality at 1 year; secondary endpoints include clinical outcomes and echocardiographic measurements, both adjudicated.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: To report 1-year outcomes of transcatheter aortic valve replacement (TAVR) with new THV system.
520 ## - SUMMARY, ETC.
Abstract RESULTS: A total of 941 patients (82.4 +/- 5.9 years, 65.7% female, STS score: 5.8%) were enrolled and underwent an implant at 61 sites in Europe, Australia and Canada. At 1 year, Kaplan-Meier estimates for all-cause mortality, cardiovascular mortality, disabling stroke rates and myocardial infarction are 12.1%, 6.6%, 2.2% and 2.5%, respectively. Mean aortic transvalvular gradient and aortic valve area were 8.66mmHg and 1.75cm<sup>2</sup> respectively. Paravalvular leakage was moderate or higher in 2.6% of patients with no severe leakage. New pacemaker rates were 18.7% and 21.3% for pacemaker naive patients at 30 days and 1 year, respectively. Functional class, exercise capacity and quality of life improved significantly from baseline to 1 year.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN PROCESS -- NOT YET INDEXED
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Asch, Federico M
790 ## - Authors
All authors Arzamendi D, Asch FM, Bedogni F, Fichtlscherer S, Hans-Peter Linke A, Kempfert J, Kuck KH, Maisano F, Rodes-Cabau J, Schafer U, Sondergaard L, Worthley S
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.jacc.2018.09.014">https://dx.doi.org/10.1016/j.jacc.2018.09.014</a>
Public note https://dx.doi.org/10.1016/j.jacc.2018.09.014
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 10/10/2018   30261238 30261238 10/10/2018 10/10/2018 Journal Article

Powered by Koha