MARC details
000 -LEADER |
fixed length control field |
03773nam a22004697a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190521s20192019 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0749-8063 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.arthro.2018.10.135 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S0749-8063(18)31019-3 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
30857900 |
245 ## - TITLE STATEMENT |
Title |
Does Pelvic Rotation Alter Radiologic Measurement of Anterior and Lateral Acetabular Coverage?. |
251 ## - Source |
Source |
Arthroscopy. 35(4):1111-1116.e1, 2019 04. |
252 ## - Abbreviated Source |
Abbreviated source |
Arthroscopy. 35(4):1111-1116.e1, 2019 04. |
252 ## - Abbreviated Source |
Former abbreviated source |
Arthroscopy. 35(4):1111-1116.e1, 2019 Apr. |
253 ## - Journal Name |
Journal name |
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2019 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2019 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2019-05-21 |
268 ## - Previous citation |
-- |
Arthroscopy. 35(4):1111-1116.e1, 2019 Apr. |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1995 - present, Available in print through MWHC library:2004 - 2007 |
520 ## - SUMMARY, ETC. |
Abstract |
CLINICAL RELEVANCE: This study emphasizes the importance of evaluating pelvic rotation when using the center edge angle to assess femoral head coverage. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: Rotation of AP and FP radiographs significantly affects the measured values of the LCEA and ACEA, respectively. The ACEA experiences more dramatic changes with rotation of the FP view compared with the LCEA with the same amount of rotation of an AP view. This study illustrates the importance of verifying the quality of the FP radiograph when using ACEA to guide therapy for hip pathology. |
520 ## - SUMMARY, ETC. |
Abstract |
Copyright (c) 2019 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Eleven dry cadaveric pelvises from an osteological collection were reconstructed and placed in anatomic position with corresponding bilateral proximal femurs. Conventional anteroposterior (AP) and false-profile (FP) pelvic radiographs were taken at 5degree increments with fluoroscopy from 0degree to 25degree of rotation. LCEA and ACEA were measured for conventional and rotated AP and FP fluoroscopic views, respectively. Statistical analysis was conducted to determine the error in ACEA and LCEA with pelvic rotation. |
520 ## - SUMMARY, ETC. |
Abstract |
PURPOSE: The purpose of this study was to determine the radiologic tolerance of the lateral center edge angle (LCEA) and anterior center edge angle (ACEA) to pelvic rotation. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: The mean LCEA was 29.1degree (95% confidence interval [CI], 25.5degree-32.7degree). Mean ACEA was 38.9degree (95% CI, 34.1degree-43.8degree). There was significant change in the LCEA past 10degree of rotation (P = .041). There was significant change in the ACEA with 5<sup>o</sup> or more of rotation (P < .001). The FP view rotated 40degree from an AP view produced 6.8degree (95% CI, 4.7-8.9) of error, whereas one rotated 90degree from an AP view produced 13.2degree (95% CI, 11.2degree-15.3degree) of error in the ACEA. An AP view rotated 25degree toward the x-ray beam produced 2.3degree (95% CI, 1.1degree-3.4degree) error, whereas one rotated 25degree away from the beam produced 2.6degree (95% CI, 1.5degree-3.8degree) of error. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Acetabulum/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Pelvis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Rotation |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cadaver |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Fluoroscopy |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
656 ## - INDEX TERM--OCCUPATION |
Department |
MedStar Union Memorial Hospital |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Gould, Heath |
790 ## - Authors |
All authors |
Gould H, Hu E, Li RT, Liu RW, Salata MJ, Valentin N |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.arthro.2018.10.135">https://dx.doi.org/10.1016/j.arthro.2018.10.135</a> |
Public note |
https://dx.doi.org/10.1016/j.arthro.2018.10.135 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |