Does Pelvic Rotation Alter Radiologic Measurement of Anterior and Lateral Acetabular Coverage?. (Record no. 4287)

MARC details
000 -LEADER
fixed length control field 03773nam a22004697a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190521s20192019 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0749-8063
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.arthro.2018.10.135 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S0749-8063(18)31019-3 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 30857900
245 ## - TITLE STATEMENT
Title Does Pelvic Rotation Alter Radiologic Measurement of Anterior and Lateral Acetabular Coverage?.
251 ## - Source
Source Arthroscopy. 35(4):1111-1116.e1, 2019 04.
252 ## - Abbreviated Source
Abbreviated source Arthroscopy. 35(4):1111-1116.e1, 2019 04.
252 ## - Abbreviated Source
Former abbreviated source Arthroscopy. 35(4):1111-1116.e1, 2019 Apr.
253 ## - Journal Name
Journal name Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2019
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2019
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2019-05-21
268 ## - Previous citation
-- Arthroscopy. 35(4):1111-1116.e1, 2019 Apr.
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 1995 - present, Available in print through MWHC library:2004 - 2007
520 ## - SUMMARY, ETC.
Abstract CLINICAL RELEVANCE: This study emphasizes the importance of evaluating pelvic rotation when using the center edge angle to assess femoral head coverage.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: Rotation of AP and FP radiographs significantly affects the measured values of the LCEA and ACEA, respectively. The ACEA experiences more dramatic changes with rotation of the FP view compared with the LCEA with the same amount of rotation of an AP view. This study illustrates the importance of verifying the quality of the FP radiograph when using ACEA to guide therapy for hip pathology.
520 ## - SUMMARY, ETC.
Abstract Copyright (c) 2019 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: Eleven dry cadaveric pelvises from an osteological collection were reconstructed and placed in anatomic position with corresponding bilateral proximal femurs. Conventional anteroposterior (AP) and false-profile (FP) pelvic radiographs were taken at 5degree increments with fluoroscopy from 0degree to 25degree of rotation. LCEA and ACEA were measured for conventional and rotated AP and FP fluoroscopic views, respectively. Statistical analysis was conducted to determine the error in ACEA and LCEA with pelvic rotation.
520 ## - SUMMARY, ETC.
Abstract PURPOSE: The purpose of this study was to determine the radiologic tolerance of the lateral center edge angle (LCEA) and anterior center edge angle (ACEA) to pelvic rotation.
520 ## - SUMMARY, ETC.
Abstract RESULTS: The mean LCEA was 29.1degree (95% confidence interval [CI], 25.5degree-32.7degree). Mean ACEA was 38.9degree (95% CI, 34.1degree-43.8degree). There was significant change in the LCEA past 10degree of rotation (P = .041). There was significant change in the ACEA with 5<sup>o</sup> or more of rotation (P < .001). The FP view rotated 40degree from an AP view produced 6.8degree (95% CI, 4.7-8.9) of error, whereas one rotated 90degree from an AP view produced 13.2degree (95% CI, 11.2degree-15.3degree) of error in the ACEA. An AP view rotated 25degree toward the x-ray beam produced 2.3degree (95% CI, 1.1degree-3.4degree) error, whereas one rotated 25degree away from the beam produced 2.6degree (95% CI, 1.5degree-3.8degree) of error.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Acetabulum/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Pelvis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Rotation
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cadaver
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Fluoroscopy
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
656 ## - INDEX TERM--OCCUPATION
Department MedStar Union Memorial Hospital
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Gould, Heath
790 ## - Authors
All authors Gould H, Hu E, Li RT, Liu RW, Salata MJ, Valentin N
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.arthro.2018.10.135">https://dx.doi.org/10.1016/j.arthro.2018.10.135</a>
Public note https://dx.doi.org/10.1016/j.arthro.2018.10.135
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 05/21/2019   30857900 30857900 05/21/2019 05/21/2019 Journal Article

Powered by Koha