Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device. (Record no. 4460)

MARC details
000 -LEADER
fixed length control field 05326nam a22006857a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190724s20192019 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1941-7640
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1161/CIRCINTERVENTIONS.119.007258 [doi]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 31296082
245 ## - TITLE STATEMENT
Title Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device.
251 ## - Source
Source Circulation: Cardiovascular Interventions. 12(7):e007258, 2019 07.
252 ## - Abbreviated Source
Abbreviated source Circ., Cardiovasc. interv.. 12(7):e007258, 2019 07.
252 ## - Abbreviated Source
Former abbreviated source Circ., Cardiovasc. interv.. 12(7):e007258, 2019 Jul.
253 ## - Journal Name
Journal name Circulation. Cardiovascular interventions
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2019
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2020
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2019-07-24
268 ## - Previous citation
-- Circulation: Cardiovascular Interventions. 12(7):e007258, 2019 Jul.
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 2008 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device.
520 ## - SUMMARY, ETC.
Abstract CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices.
520 ## - SUMMARY, ETC.
Abstract METHODS AND RESULTS: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65+/-157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Catheterization, Peripheral
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Endovascular Procedures
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Hemorrhage/pc [Prevention & Control]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Hemostatic Techniques/is [Instrumentation]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Transcatheter Aortic Valve Replacement
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Vascular Closure Devices
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged, 80 and over
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Catheterization, Peripheral/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Endovascular Procedures/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Equipment Design
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Female
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Hemorrhage/et [Etiology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Hemostatic Techniques/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Male
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element North America
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prospective Studies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Punctures
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Risk Factors
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Time Factors
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Treatment Outcome
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Vascular Closure Devices/ae [Adverse Effects]
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Ben-Dor, Itsik
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Bernardo, Nelson L
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Satler, Lowell F
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Waksman, Ron
790 ## - Authors
All authors Aziz M, Bacharach JM, Barker C, Barleben A, Ben-Dor I, Bernardo N, Bersin R, Brown D, Campbell J, Chhatriwalla AK, Coady P, Cohen DJ, Dake M, Eng M, Fearon W, Feldman T, Greenbaum A, Guerrero M, Heimansohn D, Kapadia S, Kodali S, Kozak M, Krajcer Z, Krishnaswamy A, Lauck S, Lee JT, Lumsden A, Maor N, Metzger C, Moainie S, Nanjundappa A, Nardone S, O'Neill B, O'Neill WW, Potluri S, Rodriguez R, SAFE MANTA Study Investigators, Sampson A, Sathananthan J, Satler LF, Strickman N, Szerlip M, Waksman R, Webb JG, Wood DA, Yadav P, Zhang M
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1161/CIRCINTERVENTIONS.119.007258">https://dx.doi.org/10.1161/CIRCINTERVENTIONS.119.007258</a>
Public note https://dx.doi.org/10.1161/CIRCINTERVENTIONS.119.007258
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 07/24/2019   31296082 31296082 07/24/2019 07/24/2019 Journal Article

Powered by Koha