MARC details
000 -LEADER |
fixed length control field |
03765nam a22004337a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
191105s20192019 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
2047-9980 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1161/JAHA.119.012594 [doi] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
31640455 |
245 ## - TITLE STATEMENT |
Title |
Pacemaker Implantation and Dependency After Transcatheter Aortic Valve Replacement in the REPRISE III Trial. |
251 ## - Source |
Source |
Journal of the American Heart Association. 8(21):e012594, 2019 11 05. |
252 ## - Abbreviated Source |
Abbreviated source |
J Am Heart Assoc. 8(21):e012594, 2019 11 05. |
252 ## - Abbreviated Source |
Former abbreviated source |
J Am Heart Assoc. 8(21):e012594, 2019 Nov 05. |
253 ## - Journal Name |
Journal name |
Journal of the American Heart Association |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2019 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2020 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2019-11-05 |
268 ## - Previous citation |
-- |
Journal of the American Heart Association. 8(21):e012594, 2019 Nov 05. |
520 ## - SUMMARY, ETC. |
Abstract |
Background As transcatheter aortic valve replacement expands to younger and/or lower risk patients, the long-term consequences of permanent pacemaker implantation are a concern. Pacemaker dependency and impact have not been methodically assessed in transcatheter aortic valve replacement trials. We report the incidence and predictors of pacemaker implantation and pacemaker dependency after transcatheter aortic valve replacement with the Lotus valve. Methods and Results A total of 912 patients with high/extreme surgical risk and symptomatic aortic stenosis were randomized 2:1 (Lotus:CoreValve) in REPRISE III (The Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial. Systematic assessment of pacemaker dependency was pre-specified in the trial design. Pacemaker implantation within 30 days was more frequent with Lotus than CoreValve. By multivariable analysis, predictors of pacemaker implantation included baseline right bundle branch block and depth of implantation; diabetes mellitus was also a predictor with Lotus. No association between new pacemaker implantation and clinical outcomes was found. Pacemaker dependency was dynamic (30 days: 43%; 1 year: 50%) and not consistent for individual patients over time. Predictors of pacemaker dependency at 30 days included baseline right bundle branch block, female sex, and depth of implantation. No differences in mortality or stroke were found between patients who were pacemaker dependent or not at 30 days. Rehospitalization was higher in patients who were not pacemaker dependent versus patients without a pacemaker or those who were dependent. Conclusions Pacemaker implantation was not associated with adverse clinical outcomes. Most patients with a new pacemaker at 30 days were not dependent at 1 year. Mortality and stroke were similar between patients with or without pacemaker dependency and patients without a pacemaker. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier NCT02202434. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Valve Stenosis/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Bundle-Branch Block/th [Therapy] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Pacemaker, Artificial |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Postoperative Complications/th [Therapy] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Transcatheter Aortic Valve Replacement |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Waksman, Ron |
790 ## - Authors |
All authors |
Allocco DJ, Babliaros V, Feldman TE, Iyer VS, Kereiakes DJ, Linke A, Makkar RR, Meduri CU, Meredith IT, Mishkel GJ, O'Hair D, Rajagopal V, Reardon MJ, Rizik DG, Schindler J, Stoler RC, Waksman R |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1161/JAHA.119.012594">https://dx.doi.org/10.1161/JAHA.119.012594</a> |
Public note |
https://dx.doi.org/10.1161/JAHA.119.012594 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |