Pacemaker Implantation and Dependency After Transcatheter Aortic Valve Replacement in the REPRISE III Trial. (Record no. 4708)

MARC details
000 -LEADER
fixed length control field 03765nam a22004337a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191105s20192019 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 2047-9980
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1161/JAHA.119.012594 [doi]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 31640455
245 ## - TITLE STATEMENT
Title Pacemaker Implantation and Dependency After Transcatheter Aortic Valve Replacement in the REPRISE III Trial.
251 ## - Source
Source Journal of the American Heart Association. 8(21):e012594, 2019 11 05.
252 ## - Abbreviated Source
Abbreviated source J Am Heart Assoc. 8(21):e012594, 2019 11 05.
252 ## - Abbreviated Source
Former abbreviated source J Am Heart Assoc. 8(21):e012594, 2019 Nov 05.
253 ## - Journal Name
Journal name Journal of the American Heart Association
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2019
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2020
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2019-11-05
268 ## - Previous citation
-- Journal of the American Heart Association. 8(21):e012594, 2019 Nov 05.
520 ## - SUMMARY, ETC.
Abstract Background As transcatheter aortic valve replacement expands to younger and/or lower risk patients, the long-term consequences of permanent pacemaker implantation are a concern. Pacemaker dependency and impact have not been methodically assessed in transcatheter aortic valve replacement trials. We report the incidence and predictors of pacemaker implantation and pacemaker dependency after transcatheter aortic valve replacement with the Lotus valve. Methods and Results A total of 912 patients with high/extreme surgical risk and symptomatic aortic stenosis were randomized 2:1 (Lotus:CoreValve) in REPRISE III (The Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial. Systematic assessment of pacemaker dependency was pre-specified in the trial design. Pacemaker implantation within 30 days was more frequent with Lotus than CoreValve. By multivariable analysis, predictors of pacemaker implantation included baseline right bundle branch block and depth of implantation; diabetes mellitus was also a predictor with Lotus. No association between new pacemaker implantation and clinical outcomes was found. Pacemaker dependency was dynamic (30 days: 43%; 1 year: 50%) and not consistent for individual patients over time. Predictors of pacemaker dependency at 30 days included baseline right bundle branch block, female sex, and depth of implantation. No differences in mortality or stroke were found between patients who were pacemaker dependent or not at 30 days. Rehospitalization was higher in patients who were not pacemaker dependent versus patients without a pacemaker or those who were dependent. Conclusions Pacemaker implantation was not associated with adverse clinical outcomes. Most patients with a new pacemaker at 30 days were not dependent at 1 year. Mortality and stroke were similar between patients with or without pacemaker dependency and patients without a pacemaker. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier NCT02202434.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve Stenosis/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Bundle-Branch Block/th [Therapy]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Pacemaker, Artificial
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Postoperative Complications/th [Therapy]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Transcatheter Aortic Valve Replacement
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged, 80 and over
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Female
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Male
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Waksman, Ron
790 ## - Authors
All authors Allocco DJ, Babliaros V, Feldman TE, Iyer VS, Kereiakes DJ, Linke A, Makkar RR, Meduri CU, Meredith IT, Mishkel GJ, O'Hair D, Rajagopal V, Reardon MJ, Rizik DG, Schindler J, Stoler RC, Waksman R
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1161/JAHA.119.012594">https://dx.doi.org/10.1161/JAHA.119.012594</a>
Public note https://dx.doi.org/10.1161/JAHA.119.012594
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 11/05/2019   31640455 31640455 11/05/2019 11/05/2019 Journal Article

Powered by Koha