MARC details
000 -LEADER |
fixed length control field |
02833nam a22003137a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
200902s20202020 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
2168-8184 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.7759/cureus.9224 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
PMC7430535 [pmc] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
32821573 |
245 ## - TITLE STATEMENT |
Title |
Synovial Fluid Volume at the Time of Arthroscopic Rotator Cuff Repair Correlates With Tear Size. |
251 ## - Source |
Source |
Cureus. 12(7):e9224, 2020 Jul 16. |
252 ## - Abbreviated Source |
Abbreviated source |
Cureus. 12(7):e9224, 2020 Jul 16. |
253 ## - Journal Name |
Journal name |
Cureus |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2020 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2021 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
epublish |
266 ## - Date added to catalog |
Date added to catalog |
2020-09-02 |
520 ## - SUMMARY, ETC. |
Abstract |
Background Inflammatory biomarkers are increased in the synovium and tendon of rotator cuff tears. Several studies demonstrate an associated increase in these markers and size of the tear, with implications of chondral destruction leading to rotator cuff tear arthropathy and glenohumeral arthritis. Methods This is a prospective study of 105 patients undergoing arthroscopic rotator cuff repair in which intra-articular synovial fluid was aspirated just prior to arthroscopy. Adult patients with a partial or full-thickness rotator cuff tear undergoing arthroscopic repair were included, and those with inflammatory arthritis, active infection, open cuff repair, intraoperative findings of osteoarthritis, or those undergoing revision cuff repair were excluded. Results The average patient age was 58 years (range 33-74 years), with 59 (56.2%) males. The mean aspirate volume of partial tears was 0.76 +/- 0.43 mL, small tears 1.46 +/- 1.88 mL, medium tears 3.04 +/- 2.21 mL, and large tears 6.60 +/- 3.23 mL. Full-thickness versus partial tears had significantly more synovial fluid (3.64 vs. 0.76 mL, respectively, p < 0.0001). An aspiration volume of 1.5 mL or greater resulted in 91.3% specificity and 96.8% positive predictive value for a full-thickness tear. Smoking (p = 0.017), tear size (p < 0.0001), and tears of the infraspinatus (p = 0.048) were significantly correlated with synovial fluid volume. Age, body mass index, chronicity of tear, sex, subscapularis involvement, supraspinatus involvement, and teres minor involvement had no association to synovial fluid volume. Conclusion Preoperative aspiration of the glenohumeral joint to identify the volume of synovial fluid can aid to identify full-thickness rotator cuff tears, and increased fluid volume should alert the clinician of a large tear. Copyright (c) 2020, Stone et al. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Union Memorial Hospital |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Thakar, Ocean |
790 ## - Authors |
All authors |
Abboud JA, Jamgochian G, Patel MS, Stone M, Thakar O |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.7759/cureus.9224">https://dx.doi.org/10.7759/cureus.9224</a> |
Public note |
https://dx.doi.org/10.7759/cureus.9224 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |