Comparison of Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stents and Thin, Durable-Polymer Everolimus-Eluting Stents in Calcified or Small Vessel Lesions. (Record no. 5634)

MARC details
000 -LEADER
fixed length control field 03562nam a22003857a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 201006s20202020 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1941-7640
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1161/CIRCINTERVENTIONS.120.009189 [doi]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 32895004
245 ## - TITLE STATEMENT
Title Comparison of Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stents and Thin, Durable-Polymer Everolimus-Eluting Stents in Calcified or Small Vessel Lesions.
251 ## - Source
Source Circulation: Cardiovascular Interventions. 13(9):e009189, 2020 Sep.
252 ## - Abbreviated Source
Abbreviated source Circ., Cardiovasc. interv.. 13(9):e009189, 2020 Sep.
253 ## - Journal Name
Journal name Circulation. Cardiovascular interventions
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2020
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2021
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2020-10-06
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 2008 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: The ultrathin-strut bioresorbable-polymer sirolimus-eluting stent (BP-SES) demonstrated comparable performance to durable-polymer everolimus-eluting stent (DP-EES) in randomized controlled trials. The purpose of this study was to evaluate the performance of a BP-SES compared with a DP-EES in calcified or small vessel lesions, which represent higher risk of restenosis.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: Among patients with more complex disease representing a higher risk of target lesion failure, the effectiveness of an ultrathin-strut BP-SES compared with a thin-strut DP-EES was maintained through 1 year. Registration: URL: https://www.clinicaltrials.gov. Unique identifiers: NCT01356888, NCT01939249, NCT02389946.
520 ## - SUMMARY, ETC.
Abstract METHODS: From the pooled BIOFLOW (BIOFLOW-II, IV, and V; BIOTRONIK - A Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With up to Three De Novo or Restenotic Coronary Artery Lesions ) randomized controlled trials, a total of 1553 BP-SES and 784 DP-EES patients with valid 1-year follow-up data were available. Coronary lesions were assessed for the presence of moderate-to-severe calcification or small vessels (reference vessel diameter, <=2.75 mm) by core laboratory analysis. One-year clinical outcomes were assessed with or without the lesion subsets between BP-SES and DP-EES.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Baseline characteristics were similar between the groups. Among patients with small vessel disease, target lesion failure (8.0% versus 12.4%; P<0.01) and target vessel myocardial infarction (4.2% versus 7.6%; P<0.01) were significantly lower in BP-SES than in DP-EES. No difference in the outcome between the stents was shown in patients with non-small vessel lesions. In patients with calcified lesions, target lesion failure (12.2% versus 6.9%; P=0.056), and cardiac death (1.9% versus 0.3%; P=0.081) were numerically higher in DP-EES than in BP-SES. In the noncalcified lesion analysis, target vessel myocardial infarction in DP-EES was significantly higher than in BP-SES. Stent thrombosis was similar between the stents in both lesion groups.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN PROCESS -- NOT YET INDEXED
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Dan, Kazuhiro
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Garcia-Garcia, Hector M
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Kolm, Paul
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Waksman, Ron
790 ## - Authors
All authors Dan K, Garcia-Garcia HM, Kandzari DE, Kolm P, Saito S, Waksman R, Windecker S
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1161/CIRCINTERVENTIONS.120.009189">https://dx.doi.org/10.1161/CIRCINTERVENTIONS.120.009189</a>
Public note https://dx.doi.org/10.1161/CIRCINTERVENTIONS.120.009189
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 10/06/2020   32895004 32895004 10/06/2020 10/06/2020 Journal Article

Powered by Koha