MARC details
000 -LEADER |
fixed length control field |
03002nam a22003617a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
210310s20212021 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0022-5223 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.jtcvs.2020.12.109 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S0022-5223(21)00001-5 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
33597099 |
245 ## - TITLE STATEMENT |
Title |
Midterm outcomes with a sutureless aortic bioprosthesis in a prospective multicenter cohort study. |
251 ## - Source |
Source |
Journal of Thoracic & Cardiovascular Surgery. 2021 Jan 13 |
252 ## - Abbreviated Source |
Abbreviated source |
J Thorac Cardiovasc Surg. 2021 Jan 13 |
253 ## - Journal Name |
Journal name |
The Journal of thoracic and cardiovascular surgery |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2021 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2021 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
266 ## - Date added to catalog |
Date added to catalog |
2021-03-10 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1994 - present, Available in print through MWHC library: 1999 - 2006 |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: This series, representing, to our knowledge, the longest follow-up with sutureless technology in a prospective, multicenter study, shows that aortic replacement using sutureless valves is associated with low mortality and morbidity and good hemodynamic performance. Copyright (c) 2021 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Between 2010 and 2013, 658 patients at 25 European institutions received the Perceval sutureless valve (LivaNova Plc, London, United Kingdom). Mean follow-up was 3.8 years; late cumulative follow-up was 2325.2 patient-years. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVE: The objective of this study was to report midterm clinical outcomes with a self-expandable sutureless aortic valve. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: The mean age of the population was 78.3 +/- 5.6 years and 40.0% (n = 263) were 80 years of age or older; mean Society of Thoracic Surgeons-Predicted Risk of Mortality score was 7.2 +/- 7.4. Concomitant procedures were performed in 31.5% (n = 207) of patients. Overall duration of cardiopulmonary bypass time was 64.8 +/- 25.2 minutes and aortic cross-clamping time was 40.7 +/- 18.1 minutes. Thirty-day all-cause mortality was 3.7% (23 patients), with an observed:expected ratio of 0.51. Overall survival was 91.6% at 1 year, 88.5% at 2 years, and 72.7% at 5 years. Peak and mean gradients remained stable during follow-up, and were 17.8 +/- 11.3 mm Hg and 9.0 +/- 6.3 mm Hg, respectively, at 5 years. Preoperatively, 33.4% of those who received the Perceval valve (n = 210) were in New York Heart Association functional class I or II versus 93.1% (n = 242) at 5 years. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Asch, Federico M |
790 ## - Authors |
All authors |
Asch FM, Carrel T, CAVALIER Trial Investigators, Cerutti E, Fischlein T, Folliguet T, Hakim-Meibodi K, Haverich A, Meuris B, Misfeld M, Zembala M |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.jtcvs.2020.12.109">https://dx.doi.org/10.1016/j.jtcvs.2020.12.109</a> |
Public note |
https://dx.doi.org/10.1016/j.jtcvs.2020.12.109 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |