MARC details
000 -LEADER |
fixed length control field |
04158nam a22005777a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
220124s20212021 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1547-5271 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.hrthm.2021.03.033 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S1547-5271(21)00297-6 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
33781980 |
245 ## - TITLE STATEMENT |
Title |
Low-temperature electrocautery reduces adverse effects from secondary cardiac implantable electronic device procedures: Insights from the WRAP-IT trial. |
251 ## - Source |
Source |
Heart Rhythm. 18(7):1142-1150, 2021 07. |
252 ## - Abbreviated Source |
Abbreviated source |
Heart Rhythm. 18(7):1142-1150, 2021 07. |
252 ## - Abbreviated Source |
Former abbreviated source |
Heart Rhythm. 18(7):1142-1150, 2021 07. |
253 ## - Journal Name |
Journal name |
Heart rhythm |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2021 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2021 07 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2021-06-07 |
268 ## - Previous citation |
-- |
Heart Rhythm. 18(7):1142-1150, 2021 07. |
269 ## - Original dates |
Original fiscal year |
FY2022 |
501 ## - WITH NOTE |
Local holdings |
Available online through MWHC library: 2004 - present |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Cardiac device procedures require tissue dissection to free existing device lead(s). Common techniques include blunt dissection, standard electrocautery, and low-temperature electrocautery (PlasmaBlade, Medtronic); however, data on the type of electrosurgical tool used and the development of procedure- or lead-related adverse events are limited. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: This study represents one of the largest assessments of electrocautery use in patients undergoing CIED revision, upgrade, or replacement procedures. Compared to standard electrocautery, low-temperature electrocautery significantly reduces adverse effects from these procedures. Copyright (c) 2021 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: We evaluated patients enrolled in WRAP-IT (Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial) undergoing cardiac implantable electronic device (CIED) revision, upgrade, or replacement. All adverse events were adjudicated by an independent physician committee. Data were analyzed using Cox proportional hazard regression modeling. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVE: The purpose of this study was to determine whether standard or low-temperature electrocautery impacts the development of an adverse event. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: In total, 5641 patients underwent device revision/upgrade/replacement. Electrocautery was used in 5205 patients (92.3%) (mean age 70.6 +/- 12.7 years; 28.8% female), and low-temperature electrocautery was used in 1866 patients (35.9%). Compared to standard electrocautery, low-temperature electrocautery was associated with a 23% reduction in the incidence of a procedure- or lead-related adverse event through 3 years of follow up (hazard ratio [HR] 0.77; 95% confidence interval [CI] 0.65-0.91; P = .002). After controlling for the number of active leads, degree of capsulectomy, degree of lead dissection, and renal dysfunction, low-temperature electrocautery was associated with a 32% lower risk of lead-related adverse events (HR 0.68; 95% CI 0.52-0.89; P = .004). These effects were consistent across a spectrum of lead-related adverse event types. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Arrhythmias, Cardiac/th [Therapy] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Defibrillators, Implantable/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Electrocoagulation/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Pacemaker, Artificial/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Device Removal |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Equipment Failure |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Follow-Up Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Retrospective Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Temperature |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Research Support, Non-U.S. Gov't |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Eldadah, Zayd A |
790 ## - Authors |
All authors |
Berman BJ, Eldadah Z, Holbrook R, Kennergren C, Lande JD, Lexcen DR, Love JC, Martinez-Arraras J, Mittal S, Moubarak JB, Philippon F, Pickett RA, Poole JE, Riggio D, Schaller RD, Sholevar DP, Tarakji KG, Wilkoff BL, Wright DJ |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.hrthm.2021.03.033">https://dx.doi.org/10.1016/j.hrthm.2021.03.033</a> |
Public note |
https://dx.doi.org/10.1016/j.hrthm.2021.03.033 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |