Real-time MRI-guided right heart catheterization in adults using passive catheters.

MedStar author(s):
Citation: European Heart Journal. 34(5):380-9, 2013 Feb.PMID: 22855740Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Comparative Study | Evaluation Studies | Journal Article | Research Support, N.I.H., Intramural | Video-Audio MediaSubject headings: *Cardiac Catheterization/mt [Methods] | *Heart Diseases/di [Diagnosis] | Contrast Media/du [Diagnostic Use] | Feasibility Studies | Female | Gadolinium/du [Diagnostic Use] | Humans | Magnetic Resonance Angiography/mt [Methods] | Magnetic Resonance Imaging, Interventional/mt [Methods] | Male | Middle Aged | Pilot Projects | Radiography, Interventional/mt [Methods]Year: 2013Local holdings: Available online from MWHC library: 1996 - present (after 1 year), Available in print through MWHC library: 1999 - 2006ISSN:
  • 0195-668X
Abstract: AIMS: Real-time MRI creates images with superb tissue contrast that may enable radiation-free catheterization. Simple procedures are the first step towards novel interventional procedures. We aim to perform comprehensive transfemoral diagnostic right heart catheterization in an unselected cohort of patients entirely using MRI guidance.CONCLUSION: In this early experience, comprehensive transfemoral right heart catheterization appears feasible using only MRI for imaging guidance. Gadolinium-filled balloon catheters were more conspicuous than air-filled ones. Further workflow and device enhancement are necessary for clinical adoption.METHODS AND RESULTS: We performed X-ray and MRI-guided transfemoral right heart catheterization in consecutive patients undergoing clinical cardiac catheterization. We sampled both cavae and both pulmonary arteries. We compared success rate, time to perform key steps, and catheter visibility among X-ray and MRI procedures using air-filled or gadolinium-filled balloon-tipped catheters. Sixteen subjects (four with shunt, nine with coronary artery disease, three with other) underwent paired X-ray and MRI catheterization. Complete guidewire-free catheterization was possible in 15 of 16 under both. MRI using gadolinium-filled balloons was at least as successful as X-ray in all procedure steps, more successful than MRI using air-filled balloons, and better than both in entering the left pulmonary artery. Total catheterization time and individual procedure steps required approximately the same amount of time irrespective of image guidance modality. Catheter conspicuity was best under X-ray and next-best using gadolinium-filled MRI balloons.All authors: Barbash IM, Faranesh AZ, Grant LP, Halabi M, Hansen MS, Kellman P, Kocaturk O, Lederman RJ, Ratnayaka K, Schenke WH, Stine AM, Wright VJFiscal year: FY2013Digital Object Identifier: Date added to catalog: 2013-09-17
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 22855740 Available 22855740

Available online from MWHC library: 1996 - present (after 1 year), Available in print through MWHC library: 1999 - 2006

AIMS: Real-time MRI creates images with superb tissue contrast that may enable radiation-free catheterization. Simple procedures are the first step towards novel interventional procedures. We aim to perform comprehensive transfemoral diagnostic right heart catheterization in an unselected cohort of patients entirely using MRI guidance.

CONCLUSION: In this early experience, comprehensive transfemoral right heart catheterization appears feasible using only MRI for imaging guidance. Gadolinium-filled balloon catheters were more conspicuous than air-filled ones. Further workflow and device enhancement are necessary for clinical adoption.

METHODS AND RESULTS: We performed X-ray and MRI-guided transfemoral right heart catheterization in consecutive patients undergoing clinical cardiac catheterization. We sampled both cavae and both pulmonary arteries. We compared success rate, time to perform key steps, and catheter visibility among X-ray and MRI procedures using air-filled or gadolinium-filled balloon-tipped catheters. Sixteen subjects (four with shunt, nine with coronary artery disease, three with other) underwent paired X-ray and MRI catheterization. Complete guidewire-free catheterization was possible in 15 of 16 under both. MRI using gadolinium-filled balloons was at least as successful as X-ray in all procedure steps, more successful than MRI using air-filled balloons, and better than both in entering the left pulmonary artery. Total catheterization time and individual procedure steps required approximately the same amount of time irrespective of image guidance modality. Catheter conspicuity was best under X-ray and next-best using gadolinium-filled MRI balloons.

English