Dobutamine stress echocardiography in patients undergoing orthotopic liver transplantation: a pooled analysis of accuracy, perioperative and long term cardiovascular prognosis. [Review]

MedStar author(s):
Citation: The International Journal of Cardiovascular Imaging. 29(8):1741-8, 2013 Dec.PMID: 23974907Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal Article | Meta-Analysis | ReviewSubject headings: *Cardiovascular Diseases/us [Ultrasonography] | *Coronary Artery Disease/us [Ultrasonography] | *Echocardiography, Stress | *Liver Transplantation | Cardiovascular Diseases/et [Etiology] | Cardiovascular Diseases/mo [Mortality] | Humans | Liver Transplantation/ae [Adverse Effects] | Liver Transplantation/mo [Mortality] | Predictive Value of Tests | Preoperative Care | Risk Factors | Time Factors | Treatment OutcomeYear: 2013ISSN:
  • 1569-5794
Name of journal: The international journal of cardiovascular imagingAbstract: Pre-transplant evaluation for orthotopic liver transplantation (OLT) commonly includes a cardiac evaluation using dobutamine stress echocardiography (DSE). We performed a quantitative systematic review assessing DSE's use in detecting coronary artery disease (CAD) and predicting perioperative and long term cardiac events in patients undergoing OLT. Published studies in pubmed were accessed using keyword searches and bibliographic review. Included studies evaluated the use of DSE in patients undergoing OLT, including its accuracy for detection of CAD, and in predicting perioperative and long term cardiac prognosis for both hard (myocardial infarction, cardiac death, cardiac arrest, and asystole) and soft cardiac events (all other events that were cardiovascular in nature). We calculated DSE's sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) in the above areas. We identified 7 studies, including a total of 580 patients, which included 4 accuracy studies (n = 110 patients), 4 perioperative studies, and 3 long term studies. Accuracy for CAD included a sensitivity of 0.32, specificity of 0.78, PPV of 0.37, and NPV of 0.75. Accuracy for prediction of perioperative hard and soft cardiac events was a sensitivity of 0.20 and 0, specificity of 0.99 and 0.99, PPV of 0.33 and 0, and NPV of 0.98 and 0.89, respectively. For long term hard and soft cardiac events, sensitivity was 0.5 and 0, specificity 0.99 and 0.98, PPV 0.33 and 0, and NPV 0.99 and 0.96, respectively. DSE has a limited accuracy for the detection of CAD in candidates for OLT. However, among those patients selected for OLT, the negative predictive value of DSE for both perioperative and long term cardiac events is high.All authors: Fishbein TM, Laurin JM, Nguyen P, Plotkin J, Satoskar R, Shetty K, Taylor AJFiscal year: FY2014Digital Object Identifier: Date added to catalog: 2014-08-21
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 23974907 Available 23974907

Pre-transplant evaluation for orthotopic liver transplantation (OLT) commonly includes a cardiac evaluation using dobutamine stress echocardiography (DSE). We performed a quantitative systematic review assessing DSE's use in detecting coronary artery disease (CAD) and predicting perioperative and long term cardiac events in patients undergoing OLT. Published studies in pubmed were accessed using keyword searches and bibliographic review. Included studies evaluated the use of DSE in patients undergoing OLT, including its accuracy for detection of CAD, and in predicting perioperative and long term cardiac prognosis for both hard (myocardial infarction, cardiac death, cardiac arrest, and asystole) and soft cardiac events (all other events that were cardiovascular in nature). We calculated DSE's sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) in the above areas. We identified 7 studies, including a total of 580 patients, which included 4 accuracy studies (n = 110 patients), 4 perioperative studies, and 3 long term studies. Accuracy for CAD included a sensitivity of 0.32, specificity of 0.78, PPV of 0.37, and NPV of 0.75. Accuracy for prediction of perioperative hard and soft cardiac events was a sensitivity of 0.20 and 0, specificity of 0.99 and 0.99, PPV of 0.33 and 0, and NPV of 0.98 and 0.89, respectively. For long term hard and soft cardiac events, sensitivity was 0.5 and 0, specificity 0.99 and 0.98, PPV 0.33 and 0, and NPV 0.99 and 0.96, respectively. DSE has a limited accuracy for the detection of CAD in candidates for OLT. However, among those patients selected for OLT, the negative predictive value of DSE for both perioperative and long term cardiac events is high.

English

Powered by Koha