Long-term Outcomes of Transcatheter Aortic Valve Replacement With the Lotus Valve vs CoreValve/EvolutR: A Secondary Analysis of the REPRISE III Randomized Clinical Trial.

MedStar author(s):
Citation: JAMA Network Open. 5(10):e2238792, 2022 Oct 03.PMID: 36301543Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal Article | Randomized Controlled TrialSubject headings: *Aortic Valve Stenosis | *Stroke | *Thrombosis | *Transcatheter Aortic Valve Replacement | Aged, 80 and over | Aortic Valve Stenosis/su [Surgery] | Aortic Valve/su [Surgery] | Female | Humans | Stroke/et [Etiology] | Transcatheter Aortic Valve Replacement/ae [Adverse Effects] | Transcatheter Aortic Valve Replacement/mt [Methods] | Treatment OutcomeYear: 2022ISSN:
  • 2574-3805
Name of journal: JAMA network openAbstract: Conclusions and Relevance: The REPRISE III trial found that, at 5 years, the clinical outcomes of the Lotus valve were comparable to those of the CoreValve/EvolutR and that the Lotus valve was safe and effective.Design, Setting, and Participants: This prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015. Patients had high risk for aortic stenosis or severe or symptomatic aortic stenosis. Data were analyzed from September 22, 2014, to May 21, 2021.Importance: Long-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms.Intervention: Lotus valve or CoreValve/EvolutR TAVR platforms.Main Outcomes and Measures: Valve Academic Research Consortium-2 end points, hemodynamic measures, functional status, and health status were examined through the 5-year follow-up.Objective: To describe the final 5-year outcomes of the REPRISE III trial.Results: A total of 912 patients (mean [SD] age, 82.8 [7.3] years; 463 women [50.8%]) were randomized to either the Lotus valve group (n = 607) or CoreValve/EvolutR group (n = 305), with a baseline Society of Thoracic Surgeons risk score of 6.8%. Clinical follow-up data from the REPRISE III trial were available for 581 patients (95.7%) in the Lotus valve group and 285 patients (93.4%) in the CoreValve/EvolutR group. At 5 years, the cumulative event rate for all-cause mortality was 50.9% in the Lotus valve group vs 52.8% in the CoreValve/EvolutR group (P = .59). Disabling stroke was less frequent with the Lotus valve vs CoreValve/EvolutR (cumulative event rates, 8.3% vs 12.2%; P = .04), whereas the cumulative event rates for overall stroke were similar in both groups (14.1% vs 15.3%; P = .38). Insertion of a new permanent pacemaker (38.9% vs 27.3%; P < .001) and detection of prosthetic aortic valve thrombosis (5.8% vs 1.8%; P = .007) were more common in the Lotus valve group than in the CoreValve/EvolutR group. A smaller proportion of patients who received the Lotus valve experienced valve malpositioning (0% vs 2.6%; P < .001) and required the use of a second valve (1.0% vs 3.8%; P < .001) during the procedure compared with those who received the CoreValve/EvolutR. Compared with the Lotus valve group, the CoreValve/EvolutR group had a significantly lower mean (SD) aortic gradient (7.8 [4.2] mm Hg vs 12.6 [6.7] mm Hg; P < .001) and larger valve areas (1.57 [0.56] cm2 vs 1.42 [0.42] cm2; P = .10). After 5 years, the proportion of patients with moderate or greater paravalvular leak was not significantly higher with the CoreValve/EvolutR than with the Lotus valve (1.9% vs 0%; P = .31); however, the proportion of patients with mild paravalvular leak was higher in the CoreValve/EvolutR group compared with the Lotus valve group (23.1% vs 7.8%; P = .006). Long-term, similar improvements in New York Heart Association class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups.Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.All authors: Allocco DJ, Bajwa T, Bjursten H, Buchbinder M, Gotberg M, Iyer VS, Kereiakes DJ, Kleiman NS, Linke A, Makkar RR, Mishkel GJ, Rajagopal V, Reardon MJ, Rizik DG, Stoler RC, Thourani VH, Waksman RFiscal year: FY2023Digital Object Identifier: Date added to catalog: 2022-12-13
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 36301543 Available 36301543

Conclusions and Relevance: The REPRISE III trial found that, at 5 years, the clinical outcomes of the Lotus valve were comparable to those of the CoreValve/EvolutR and that the Lotus valve was safe and effective.

Design, Setting, and Participants: This prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015. Patients had high risk for aortic stenosis or severe or symptomatic aortic stenosis. Data were analyzed from September 22, 2014, to May 21, 2021.

Importance: Long-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms.

Intervention: Lotus valve or CoreValve/EvolutR TAVR platforms.

Main Outcomes and Measures: Valve Academic Research Consortium-2 end points, hemodynamic measures, functional status, and health status were examined through the 5-year follow-up.

Objective: To describe the final 5-year outcomes of the REPRISE III trial.

Results: A total of 912 patients (mean [SD] age, 82.8 [7.3] years; 463 women [50.8%]) were randomized to either the Lotus valve group (n = 607) or CoreValve/EvolutR group (n = 305), with a baseline Society of Thoracic Surgeons risk score of 6.8%. Clinical follow-up data from the REPRISE III trial were available for 581 patients (95.7%) in the Lotus valve group and 285 patients (93.4%) in the CoreValve/EvolutR group. At 5 years, the cumulative event rate for all-cause mortality was 50.9% in the Lotus valve group vs 52.8% in the CoreValve/EvolutR group (P = .59). Disabling stroke was less frequent with the Lotus valve vs CoreValve/EvolutR (cumulative event rates, 8.3% vs 12.2%; P = .04), whereas the cumulative event rates for overall stroke were similar in both groups (14.1% vs 15.3%; P = .38). Insertion of a new permanent pacemaker (38.9% vs 27.3%; P < .001) and detection of prosthetic aortic valve thrombosis (5.8% vs 1.8%; P = .007) were more common in the Lotus valve group than in the CoreValve/EvolutR group. A smaller proportion of patients who received the Lotus valve experienced valve malpositioning (0% vs 2.6%; P < .001) and required the use of a second valve (1.0% vs 3.8%; P < .001) during the procedure compared with those who received the CoreValve/EvolutR. Compared with the Lotus valve group, the CoreValve/EvolutR group had a significantly lower mean (SD) aortic gradient (7.8 [4.2] mm Hg vs 12.6 [6.7] mm Hg; P < .001) and larger valve areas (1.57 [0.56] cm2 vs 1.42 [0.42] cm2; P = .10). After 5 years, the proportion of patients with moderate or greater paravalvular leak was not significantly higher with the CoreValve/EvolutR than with the Lotus valve (1.9% vs 0%; P = .31); however, the proportion of patients with mild paravalvular leak was higher in the CoreValve/EvolutR group compared with the Lotus valve group (23.1% vs 7.8%; P = .006). Long-term, similar improvements in New York Heart Association class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups.

Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.