Assessing the Accuracy of Ultrasound-Guided Needle Placement in Sacroiliac Joint Injections.

MedStar author(s):
Citation: American Journal of Physical Medicine & Rehabilitation. 98(8):666-670, 2019 Aug.PMID: 31318746Institution: MedStar National Rehabilitation NetworkForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: IN PROCESS -- NOT YET INDEXEDYear: 2019Local holdings: Available online from MWHC library: 1996 - presentISSN:
  • 0894-9115
Name of journal: American journal of physical medicine & rehabilitationAbstract: CONCLUSIONS: Ultrasound-guided injection of the sacroiliac joint is successful and accurate upon confirmation of fluoroscopic arthrogram and should be used as an imaging modality for needle guidance.DESIGN: Institutional review board approval was gained for a prospective cohort study of 50 patients (N = 50). Study patients who were referred for sacroiliac joint injections for sacroiliac joint mediate pain and met inclusion/exclusion criteria were enrolled in the study. Each patient underwent needle placement with ultrasound guidance in the procedure suite. After the needle was placed with the ultrasound guidance, fluoroscopy was used to confirm correct placement via contrast injection confirming a sacroiliac joint arthrogram. The arthrogram was confirmed via the performing physician and radiologist.OBJECTIVE: The aim of the study was to assess the accuracy of ultrasound-guided needle placement for sacroiliac joint injections.RESULTS: The placement of the needle with ultrasound guidance into the sacroiliac joint was confirmed successful in 96% (48/50) patients by fluoroscopic arthrogram. The two patients with unsuccessful arthrograms after initial placement of the needle with ultrasound were morbidly obese. There was intravascular uptake during the arthrogram of one patient who had a successful arthrogram.All authors: De Luigi AJ, Mathur R, Saini A, Saini V, Yokel NFiscal year: FY2020Digital Object Identifier: Date added to catalog: 2019-08-23
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 31318746 Available 31318746

Available online from MWHC library: 1996 - present

CONCLUSIONS: Ultrasound-guided injection of the sacroiliac joint is successful and accurate upon confirmation of fluoroscopic arthrogram and should be used as an imaging modality for needle guidance.

DESIGN: Institutional review board approval was gained for a prospective cohort study of 50 patients (N = 50). Study patients who were referred for sacroiliac joint injections for sacroiliac joint mediate pain and met inclusion/exclusion criteria were enrolled in the study. Each patient underwent needle placement with ultrasound guidance in the procedure suite. After the needle was placed with the ultrasound guidance, fluoroscopy was used to confirm correct placement via contrast injection confirming a sacroiliac joint arthrogram. The arthrogram was confirmed via the performing physician and radiologist.

OBJECTIVE: The aim of the study was to assess the accuracy of ultrasound-guided needle placement for sacroiliac joint injections.

RESULTS: The placement of the needle with ultrasound guidance into the sacroiliac joint was confirmed successful in 96% (48/50) patients by fluoroscopic arthrogram. The two patients with unsuccessful arthrograms after initial placement of the needle with ultrasound were morbidly obese. There was intravascular uptake during the arthrogram of one patient who had a successful arthrogram.