Clinical Implications of Physical Function and Resilience in Patients Undergoing Transcatheter Aortic Valve Replacement.

MedStar author(s):
Citation: Journal of the American Heart Association. 9(17):e017075, 2020 09.PMID: 32856530Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: *Aortic Valve Stenosis/su [Surgery] | *Frailty/co [Complications] | *Physical Fitness/ph [Physiology] | *Transcatheter Aortic Valve Replacement/ae [Adverse Effects] | *Walking Speed/ph [Physiology] | Aged | Aged, 80 and over | Case-Control Studies | Female | Frailty/ep [Epidemiology] | Heart Valve Prosthesis Implantation/ae [Adverse Effects] | Heart Valve Prosthesis/ae [Adverse Effects] | Hospitalization/sn [Statistics & Numerical Data] | Humans | Male | Postoperative Complications/mo [Mortality] | Prevalence | Proportional Hazards Models | Resilience, Psychological | Risk Factors | Transcatheter Aortic Valve Replacement/mo [Mortality] | Treatment OutcomeYear: 2020ISSN:
  • 2047-9980
Name of journal: Journal of the American Heart AssociationAbstract: Background Gait speed is a reliable measure of physical function and frailty in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Slow gait speed pre-TAVR predicts worse clinical outcomes post-TAVR. The consequences of improved versus worsened physical function post-TAVR are unknown. Methods and Results The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial randomized high/extreme risk patients to receive a mechanically-expanded or self-expanding transcatheter heart valve. Of 874 patients who underwent TAVR, 576 with complete data at baseline and 1 year were included in this analysis. Slow gait speed in the 5-m walk test was defined as <0.83 m/s. A clinically meaningful improvement (>=0.1 m/s) in gait speed 1 year after TAVR occurred in 39% of patients, 35% exhibited no change, and 26% declined (>=0.1 m/s). Among groups defined by baseline/1-year post-TAVR gait speeds, 1- to 2-year mortality or hospitalization rates were as follows: 6.6% (normal/normal), 8.0% (slow/normal), 20.9% (normal/slow), and 21.5% (slow/slow). After adjustment, slow gait speed at 1 year (regardless of baseline speed) was associated with a 3.5-fold increase in death/hospitalization between 1 and 2 years compared with those with normal baseline/1-year gait speed. Patients whose slow gait speed normalized at 1 year had no increased risk. One-year, but not baseline, gait speed was associated with death or hospitalization between 1 and 2 years (adjusted hazard ratio, 0.83 per 0.1 m/s faster gait; 95% CI, 0.74-0.93, P=0.001). Conclusions Marked heterogeneity exists in the trajectory of physical function after TAVR and this, more than baseline function, has clinical consequences. Identifying and optimizing factors associated with physical resilience after TAVR may improve outcomes. Registration URL: https://www.clini caltr ials.gov; Unique identifier: NCT02202434.All authors: Allocco DJ, Bajwa T, Barker CM, Goel K, Kereiakes DJ, Kleiman N, Levack M, Lindman BR, Linke A, Makkar RR, O'Leary JM, Rajagopal V, Reardon MJ, Rizik DG, Waksman ROriginally published: Journal of the American Heart Association. 9(17):e017075, 2020 Sep.Fiscal year: FY2021Digital Object Identifier: Date added to catalog: 2020-10-06
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 32856530 Available 32856530

Background Gait speed is a reliable measure of physical function and frailty in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Slow gait speed pre-TAVR predicts worse clinical outcomes post-TAVR. The consequences of improved versus worsened physical function post-TAVR are unknown. Methods and Results The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial randomized high/extreme risk patients to receive a mechanically-expanded or self-expanding transcatheter heart valve. Of 874 patients who underwent TAVR, 576 with complete data at baseline and 1 year were included in this analysis. Slow gait speed in the 5-m walk test was defined as <0.83 m/s. A clinically meaningful improvement (>=0.1 m/s) in gait speed 1 year after TAVR occurred in 39% of patients, 35% exhibited no change, and 26% declined (>=0.1 m/s). Among groups defined by baseline/1-year post-TAVR gait speeds, 1- to 2-year mortality or hospitalization rates were as follows: 6.6% (normal/normal), 8.0% (slow/normal), 20.9% (normal/slow), and 21.5% (slow/slow). After adjustment, slow gait speed at 1 year (regardless of baseline speed) was associated with a 3.5-fold increase in death/hospitalization between 1 and 2 years compared with those with normal baseline/1-year gait speed. Patients whose slow gait speed normalized at 1 year had no increased risk. One-year, but not baseline, gait speed was associated with death or hospitalization between 1 and 2 years (adjusted hazard ratio, 0.83 per 0.1 m/s faster gait; 95% CI, 0.74-0.93, P=0.001). Conclusions Marked heterogeneity exists in the trajectory of physical function after TAVR and this, more than baseline function, has clinical consequences. Identifying and optimizing factors associated with physical resilience after TAVR may improve outcomes. Registration URL: https://www.clini caltr ials.gov; Unique identifier: NCT02202434.

English

Powered by Koha