Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial.

MedStar author(s):
Citation: Journal of the American College of Cardiology. 76(16):1830-1843, 2020 10 20.PMID: 33059828Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: *Aortic Valve Insufficiency/di [Diagnosis] | *Aortic Valve Insufficiency/su [Surgery] | *Bioprosthesis | *Heart Valve Prosthesis | *Prosthesis Failure | *Transcatheter Aortic Valve Replacement/mt [Methods] | Aged | Aged, 80 and over | Aortic Valve Insufficiency/pp [Physiopathology] | Bioprosthesis/td [Trends] | Female | Heart Valve Prosthesis/td [Trends] | Humans | Male | Prosthesis Failure/td [Trends] | Transcatheter Aortic Valve Replacement/is [Instrumentation] | Transcatheter Aortic Valve Replacement/td [Trends]Year: 2020Local holdings: Available online from MWHC library: 1995 - present, Available in print through MWHC library:1999-2007ISSN:
  • 0735-1097
Name of journal: Journal of the American College of CardiologyAbstract: BACKGROUND: It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD.CONCLUSIONS: Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII A [PARTNERII A]; NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128). Copyright (c) 2020 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.METHODS: In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years.OBJECTIVES: This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry.RESULTS: Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 +/- 0.24% vs. 0.63 +/- 0.16%), SVD-related BVF (0.58 +/- 0.14% vs. 0.12 +/- 0.07%), and all-cause (structural or nonstructural) BVF (0.81 +/- 0.16% vs. 0.27 +/- 0.10%) (p <= 0.01 for all). The 5-year rates of SVD (0.68 +/- 0.18% vs. 0.60 +/- 0.17%; p = 0.71), SVD-related BVF (0.29 +/- 0.12% vs. 0.14 +/- 0.08%; p = 0.25), and all-cause BVF (0.60 +/- 0.15% vs. 0.32 +/- 0.11%; p = 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts.All authors: Alu MC, Annabi MS, Asch FM, Beaudoin J, Bernier M, Blanke P, Clavel MA, Dahou A, Douglas PS, Guzzetti E, Hahn RT, Herrmann HC, Jaber WA, Kapadia SR, Kodali SK, Leipsic J, Leon MB, Mack MJ, Makkar R, Miller DC, PARTNER 2 Investigators, Pibarot P, Rodriguez L, Rogers E, Salaun E, Smith CR, Ternacle J, Thourani VH, Webb JG, Weissman NJ, Xu KOriginally published: Journal of the American College of Cardiology. 76(16):1830-1843, 2020 Oct 20.Fiscal year: FY2021Digital Object Identifier: Date added to catalog: 2020-12-29
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 33059828 Available 33059828

Available online from MWHC library: 1995 - present, Available in print through MWHC library:1999-2007

BACKGROUND: It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD.

CONCLUSIONS: Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII A [PARTNERII A]; NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128). Copyright (c) 2020 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

METHODS: In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years.

OBJECTIVES: This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry.

RESULTS: Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 +/- 0.24% vs. 0.63 +/- 0.16%), SVD-related BVF (0.58 +/- 0.14% vs. 0.12 +/- 0.07%), and all-cause (structural or nonstructural) BVF (0.81 +/- 0.16% vs. 0.27 +/- 0.10%) (p <= 0.01 for all). The 5-year rates of SVD (0.68 +/- 0.18% vs. 0.60 +/- 0.17%; p = 0.71), SVD-related BVF (0.29 +/- 0.12% vs. 0.14 +/- 0.08%; p = 0.25), and all-cause BVF (0.60 +/- 0.15% vs. 0.32 +/- 0.11%; p = 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts.