Comparison of Lag Versus Nonlag Screw Fixation for Long Oblique Proximal Phalanx Fractures: A Biomechanical Study.

MedStar author(s):
Citation: Journal of Hand Surgery - American Volume. 2021 Jul 08PMID: 34247847Institution: Curtis National Hand Center | MedStar Union Memorial Hospital | MedStar Washington Hospital CenterDepartment: Orthopaedic Surgery ResidencyForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: IN PROCESS -- NOT YET INDEXEDYear: 2021Local holdings: Available in print through MWHC library: 1999 - 2002, Available online from MWHC library: 1995 - presentName of journal: The Journal of hand surgeryAbstract: CLINICAL RELEVANCE: Fixation of long oblique P1 fractures with nonlag screws has the potential to simplify treatment without sacrificing fracture stability during immediate postoperative range of motion. Copyright (c) 2021 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.CONCLUSIONS: Nonlag screws provided equivalent biomechanical stability to lag screws for simulated long oblique P1 fractures during cyclic testing in this cadaveric model.METHODS: We simulated long oblique P1 fractures with a 45degree oblique cut in the index, middle, and ring fingers of 4 matched pairs of cadaveric hands for a total of 24 simulated fractures. Fractures were stabilized using 1 of 3 techniques: two 1.5-mm fully threaded bicortical screws using a lag technique, two 1.5-mm fully threaded bicortical nonlag screws, or 2 crossed 1.14-mm K-wires as a separate control. The fixation method was randomized for each of the 3 fractures per matched-pair hand, with each fixation being used in each hand and 8 total P1 fractures per fixation group. Hands were mounted to a custom frame where a computer-controlled, motor-driven, linear actuator powered movement of the flexor and extensor tendons. All fingers underwent 2,000 full flexion and extension cycles. Maximum interfragmentary displacement was continuously measured using a differential variable reluctance transducer. Our primary outcome was the difference in the mean P1 fragment displacement between lag and nonlag screw fixation at 2,000 cycles.PURPOSE: To compare lag versus nonlag screw fixation for long oblique proximal phalanx (P1) fractures in a cadaveric model of finger motion via the flexor and extensor tendons.RESULTS: The observed differences in mean displacement between lag and nonlag screw fixation were not statistically significant throughout all time points. A two one-sided test procedure for paired samples confirmed statistical equivalence in the fragment displacement between these fixation methods at all time points, including the primary end point of 2,000 cycles.All authors: Green T, Means KR Jr, Miles MR, Parks BG, Segalman KA, Thakkar MYFiscal year: FY2022Digital Object Identifier: Date added to catalog: 2021-07-26
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 34247847 Available 34247847

Available in print through MWHC library: 1999 - 2002, Available online from MWHC library: 1995 - present

CLINICAL RELEVANCE: Fixation of long oblique P1 fractures with nonlag screws has the potential to simplify treatment without sacrificing fracture stability during immediate postoperative range of motion. Copyright (c) 2021 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

CONCLUSIONS: Nonlag screws provided equivalent biomechanical stability to lag screws for simulated long oblique P1 fractures during cyclic testing in this cadaveric model.

METHODS: We simulated long oblique P1 fractures with a 45degree oblique cut in the index, middle, and ring fingers of 4 matched pairs of cadaveric hands for a total of 24 simulated fractures. Fractures were stabilized using 1 of 3 techniques: two 1.5-mm fully threaded bicortical screws using a lag technique, two 1.5-mm fully threaded bicortical nonlag screws, or 2 crossed 1.14-mm K-wires as a separate control. The fixation method was randomized for each of the 3 fractures per matched-pair hand, with each fixation being used in each hand and 8 total P1 fractures per fixation group. Hands were mounted to a custom frame where a computer-controlled, motor-driven, linear actuator powered movement of the flexor and extensor tendons. All fingers underwent 2,000 full flexion and extension cycles. Maximum interfragmentary displacement was continuously measured using a differential variable reluctance transducer. Our primary outcome was the difference in the mean P1 fragment displacement between lag and nonlag screw fixation at 2,000 cycles.

PURPOSE: To compare lag versus nonlag screw fixation for long oblique proximal phalanx (P1) fractures in a cadaveric model of finger motion via the flexor and extensor tendons.

RESULTS: The observed differences in mean displacement between lag and nonlag screw fixation were not statistically significant throughout all time points. A two one-sided test procedure for paired samples confirmed statistical equivalence in the fragment displacement between these fixation methods at all time points, including the primary end point of 2,000 cycles.

English

Powered by Koha