Citation: Jacc: Cardiovascular Interventions. 14(13):1466-1477, 2021 07 12.PMID: 34238557Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: *Aortic Valve Stenosis | *Heart Valve Prosthesis | *Heart Valve Prosthesis Implantation | *Transcatheter Aortic Valve Replacement | Aortic Valve Stenosis/dg [Diagnostic Imaging] | Aortic Valve Stenosis/su [Surgery] | Aortic Valve/dg [Diagnostic Imaging] | Aortic Valve/su [Surgery] | Heart Valve Prosthesis Implantation/ae [Adverse Effects] | Humans | Prosthesis Design | Registries | Risk Factors | Transcatheter Aortic Valve Replacement/ae [Adverse Effects] | Treatment OutcomeYear: 2021Local holdings: Available online through MWHC library: 2008 - presentName of journal: JACC. Cardiovascular interventionsAbstract: BACKGROUND: TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series.CONCLUSIONS: EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. Copyright (c) 2021 The Authors. Published by Elsevier Inc. All rights reserved.METHODS: The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <=0.85 cm2/m2 (<=0.70 if obese: body mass index >=30 kg/m2) and severe if EOAi <=0.65 cm2/m2 (<=0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization.OBJECTIVES: This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR).RESULTS: The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR.All authors: Abbas AE, Alu M, Annabi MS, Bax J, Beaudoin J, Bernier M, Blanke P, Clavel MA, Dahou A, Douglas P, Guzzetti E, Hahn RT, Herrmann HC, Jaber W, Khalique OK, Kodali S, Leipsic J, Leon M, Mack MJ, Pibarot P, Rogers E, Salaun E, Ternacle J, Thourani VH, Weissman NJ, Xu KOriginally published: Jacc: Cardiovascular Interventions. 14(13):1466-1477, 2021 Jul 12.Fiscal year: FY2022Fiscal year of original publication: FY2022Digital Object Identifier: Date added to catalog: 2021-07-26
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 34238557 Available 34238557

Available online through MWHC library: 2008 - present

BACKGROUND: TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series.

CONCLUSIONS: EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. Copyright (c) 2021 The Authors. Published by Elsevier Inc. All rights reserved.

METHODS: The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <=0.85 cm2/m2 (<=0.70 if obese: body mass index >=30 kg/m2) and severe if EOAi <=0.65 cm2/m2 (<=0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization.

OBJECTIVES: This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR).

RESULTS: The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR.