Evaluation of healing outcomes combining a novel polymer formulation with autologous skin cell suspension to treat deep partial and full thickness wounds in a porcine model: a pilot study.

MedStar author(s):
Citation: Burns. 2022 Jan 21PMID: 35151510Institution: MedStar Georgetown University Hospital/MedStar Washington Hospital Center | MedStar Health Research InstituteDepartment: Firefighters' Burn and Surgical Research Laboratory | MedStar General Surgery ResidencyForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: IN PROCESS -- NOT YET INDEXEDYear: 2022Local holdings: Available online from MWHC library: 1995 - present, Available in print through MWHC library:1996-2007ISSN:
  • 0305-4179
Name of journal: Burns : journal of the International Society for Burn InjuriesAbstract: Autologous skin cell suspensions (ASCS) can treat burns of varying depths with the advantage of reduced donor site wound burden. The current standard primary dressing for ASCS is a nonabsorbant, non-adherent, perforated film (control) which has limited conformability over heterogeneous wound beds and allows for run-off of the ASCS. To address these concerns, a novel spray-on polymer formulation was tested as a potential primary dressing in porcine deep partial thickness (DPT) and full thickness (FT) wounds. It was hypothesized that the polymer would perform as well as control dressing when evaluating wound healing and scarring. DPT or FT wounds were treated with either a spray-on poly(lactic-co-glycolic acid) (PLGA) and poly(lactide-co-caprolactone) (PLCL) formulation or control ASCS dressings. Throughout the experimental time course (to day 50), we found no significant differences between polymer and control wounds in % re-epithelialization, graft-loss, epidermal or dermal thickness, or % dermal cellularity in either model. Pigmentation, erythema, elasticity, and trans-epidermal water loss (TEWL), were not significantly altered between the treatment groups, but differences between healing wounds/scars and un-injured skin were observed. No cytotoxic effect was observed in ASCS incubated with the PLGA and PLCL polymers. These data suggest that the novel spray-on polymer is a viable option as a primary dressing, with improved ease of application and conformation to irregular wounds. Polymer formulation and application technique should be a subject of future research. Copyright © 2022 The Authors. Published by Elsevier Ltd.. All rights reserved.All authors: Carney BC, Daristotle JL, Erdi M, Keyloun JW, Kirkpatrick LD, Kofinas P, Moffatt LT, Oliver MA, Rozyyev S, Sandler AD, Saruwatari MS, Shupp JW, Tranchina SPFiscal year: FY2022Digital Object Identifier: Date added to catalog: 2022-02-22
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 35151510 Available 35151510

Available online from MWHC library: 1995 - present, Available in print through MWHC library:1996-2007

Autologous skin cell suspensions (ASCS) can treat burns of varying depths with the advantage of reduced donor site wound burden. The current standard primary dressing for ASCS is a nonabsorbant, non-adherent, perforated film (control) which has limited conformability over heterogeneous wound beds and allows for run-off of the ASCS. To address these concerns, a novel spray-on polymer formulation was tested as a potential primary dressing in porcine deep partial thickness (DPT) and full thickness (FT) wounds. It was hypothesized that the polymer would perform as well as control dressing when evaluating wound healing and scarring. DPT or FT wounds were treated with either a spray-on poly(lactic-co-glycolic acid) (PLGA) and poly(lactide-co-caprolactone) (PLCL) formulation or control ASCS dressings. Throughout the experimental time course (to day 50), we found no significant differences between polymer and control wounds in % re-epithelialization, graft-loss, epidermal or dermal thickness, or % dermal cellularity in either model. Pigmentation, erythema, elasticity, and trans-epidermal water loss (TEWL), were not significantly altered between the treatment groups, but differences between healing wounds/scars and un-injured skin were observed. No cytotoxic effect was observed in ASCS incubated with the PLGA and PLCL polymers. These data suggest that the novel spray-on polymer is a viable option as a primary dressing, with improved ease of application and conformation to irregular wounds. Polymer formulation and application technique should be a subject of future research. Copyright © 2022 The Authors. Published by Elsevier Ltd.. All rights reserved.