Self-expanding and balloon-expandable valves in low risk TAVR patients. - 2024

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242. Copyright © 2023 Elsevier B.V. All rights reserved. CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (>=moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 +/- 0.43 mm2 vs. 1.69 +/- 0.45 mm2, p < 0.001) and lower mean gradient (8.93 +/- 3.53 mmHg vs. 13.41 +/- 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038).


English

0167-5273

10.1016/j.ijcard.2023.131431 [doi] S0167-5273(23)01461-4 [pii]


*Aortic Valve Stenosis
*Heart Valve Prosthesis
*Stroke
*Thrombosis
*Transcatheter Aortic Valve Replacement
Aortic Valve Stenosis/di [Diagnosis]
Aortic Valve Stenosis/et [Etiology]
Aortic Valve Stenosis/su [Surgery]
Aortic Valve/dg [Diagnostic Imaging]
Aortic Valve/su [Surgery]
Humans
Prosthesis Design
Risk Factors
Stroke/et [Etiology]
Thrombosis/et [Etiology]
Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
Treatment Outcome


MedStar Health Research Institute
MedStar Heart & Vascular Institute
MedStar Washington Hospital Center


Interventional Cardiology Fellowship


Journal Article