TY - BOOK AU - Eldadah, Zayd A TI - Low-temperature electrocautery reduces adverse effects from secondary cardiac implantable electronic device procedures: Insights from the WRAP-IT trial SN - 1547-5271 PY - 2021/// KW - *Arrhythmias, Cardiac/th [Therapy] KW - *Defibrillators, Implantable/ae [Adverse Effects] KW - *Electrocoagulation/mt [Methods] KW - *Pacemaker, Artificial/ae [Adverse Effects] KW - Aged KW - Device Removal KW - Equipment Failure KW - Female KW - Follow-Up Studies KW - Humans KW - Male KW - Retrospective Studies KW - Temperature KW - MedStar Heart & Vascular Institute KW - Journal Article KW - Research Support, Non-U.S. Gov't N1 - Available online through MWHC library: 2004 - present N2 - BACKGROUND: Cardiac device procedures require tissue dissection to free existing device lead(s). Common techniques include blunt dissection, standard electrocautery, and low-temperature electrocautery (PlasmaBlade, Medtronic); however, data on the type of electrosurgical tool used and the development of procedure- or lead-related adverse events are limited; CONCLUSION: This study represents one of the largest assessments of electrocautery use in patients undergoing CIED revision, upgrade, or replacement procedures. Compared to standard electrocautery, low-temperature electrocautery significantly reduces adverse effects from these procedures. Copyright (c) 2021 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved; METHODS: We evaluated patients enrolled in WRAP-IT (Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial) undergoing cardiac implantable electronic device (CIED) revision, upgrade, or replacement. All adverse events were adjudicated by an independent physician committee. Data were analyzed using Cox proportional hazard regression modeling; OBJECTIVE: The purpose of this study was to determine whether standard or low-temperature electrocautery impacts the development of an adverse event; RESULTS: In total, 5641 patients underwent device revision/upgrade/replacement. Electrocautery was used in 5205 patients (92.3%) (mean age 70.6 +/- 12.7 years; 28.8% female), and low-temperature electrocautery was used in 1866 patients (35.9%). Compared to standard electrocautery, low-temperature electrocautery was associated with a 23% reduction in the incidence of a procedure- or lead-related adverse event through 3 years of follow up (hazard ratio [HR] 0.77; 95% confidence interval [CI] 0.65-0.91; P = .002). After controlling for the number of active leads, degree of capsulectomy, degree of lead dissection, and renal dysfunction, low-temperature electrocautery was associated with a 32% lower risk of lead-related adverse events (HR 0.68; 95% CI 0.52-0.89; P = .004). These effects were consistent across a spectrum of lead-related adverse event types UR - https://dx.doi.org/10.1016/j.hrthm.2021.03.033 ER -