100 Complex posterior spinal fusion cases performed with robotic instrumentation.

MedStar author(s):
Citation: Journal of Robotic Surgery. 2023 Sep 14PMID: 37707742Institution: MedStar Union Memorial HospitalDepartment: MedStar Georgetown University Hospital/MedStar Washington Hospital Center | Orthopaedic Surgery | Orthopaedic Surgery Residency | Spine CenterForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: IN PROCESS -- NOT YET INDEXED | Year: 2023ISSN:
  • 1863-2483
Name of journal: Journal of robotic surgeryAbstract: Robotic navigation has been shown to increase precision, accuracy, and safety during spinal reconstructive procedures. There is a paucity of literature describing the best techniques for robotic-assisted spine surgery for complex, multilevel cases or in cases of significant deformity correction. We present a case series of 100 consecutive multilevel posterior spinal fusion procedures performed for multilevel spinal disease and/or deformity correction. 100 consecutive posterior spinal fusions were performed for multilevel disease and/or deformity correction utilizing robotic-assisted placement of pedicle screws. The primary outcome was surgery-related failure, which was defined as hardware breakage or reoperation with removal of hardware. A total of 100 consecutive patients met inclusion criteria. Among cases included, 31 were revision surgeries with existing hardware in place. The mean number of levels fused was 5.6, the mean operative time was 303 min, and the mean estimated blood loss was 469 mL. 28 cases included robotic-assisted placement of S2 alar-iliac (S2AI) screws. In total, 1043 pedicle screws and 53 S2AI screws were placed with robotic-assistance. The failure rate using survivorship analysis was 18/1043 (1.7%) and the failure rate of S2AI screws using survivorship analysis was 3/53 (5.7%). Four patients developed postoperative wound infections requiring irrigation and debridement procedures. None of the 1043 pedicle screws nor the 53 S2AI screws required reoperation due to malpositioning or suboptimal placement. This case series of 100 multilevel posterior spinal fusion procedures demonstrates promising results with low failure rates. With 1043 pedicle screws and 53 S2AI screws, we report low failure rates of 1.7% and 5.7%, respectively with zero cases of screw malpositioning. Robotic screw placement allows for accurate screw placement with no increased rate of postoperative infection compared to historical controls. Level of evidence: IV, Retrospective review. Copyright © 2023. The Author(s), under exclusive licence to Springer-Verlag London Ltd., part of Springer Nature.All authors: McCormick B, Asdourian PL, Johnson DC, Moatz BW, Duvall GT, Soda MT, Beaufort AR, Chotikul LG, McAfee PCFiscal year: FY2024Digital Object Identifier: Date added to catalog: 2023-12-20
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 37707742 Available 37707742

Robotic navigation has been shown to increase precision, accuracy, and safety during spinal reconstructive procedures. There is a paucity of literature describing the best techniques for robotic-assisted spine surgery for complex, multilevel cases or in cases of significant deformity correction. We present a case series of 100 consecutive multilevel posterior spinal fusion procedures performed for multilevel spinal disease and/or deformity correction. 100 consecutive posterior spinal fusions were performed for multilevel disease and/or deformity correction utilizing robotic-assisted placement of pedicle screws. The primary outcome was surgery-related failure, which was defined as hardware breakage or reoperation with removal of hardware. A total of 100 consecutive patients met inclusion criteria. Among cases included, 31 were revision surgeries with existing hardware in place. The mean number of levels fused was 5.6, the mean operative time was 303 min, and the mean estimated blood loss was 469 mL. 28 cases included robotic-assisted placement of S2 alar-iliac (S2AI) screws. In total, 1043 pedicle screws and 53 S2AI screws were placed with robotic-assistance. The failure rate using survivorship analysis was 18/1043 (1.7%) and the failure rate of S2AI screws using survivorship analysis was 3/53 (5.7%). Four patients developed postoperative wound infections requiring irrigation and debridement procedures. None of the 1043 pedicle screws nor the 53 S2AI screws required reoperation due to malpositioning or suboptimal placement. This case series of 100 multilevel posterior spinal fusion procedures demonstrates promising results with low failure rates. With 1043 pedicle screws and 53 S2AI screws, we report low failure rates of 1.7% and 5.7%, respectively with zero cases of screw malpositioning. Robotic screw placement allows for accurate screw placement with no increased rate of postoperative infection compared to historical controls. Level of evidence: IV, Retrospective review. Copyright © 2023. The Author(s), under exclusive licence to Springer-Verlag London Ltd., part of Springer Nature.

English

Powered by Koha