Safety and efficacy of the XIENCE V everolimus-eluting stent compared to first-generation drug-eluting stents in contemporary clinical practice.

MedStar author(s):
Citation: American Journal of Cardiology. 109(9):1288-94, 2012 May 1.PMID: 22341925Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Comparative Study | Journal Article | Randomized Controlled Trial | Research Support, Non-U.S. Gov'tSubject headings: *Angioplasty, Balloon, Coronary/mt [Methods] | *Coronary Artery Disease/th [Therapy] | *Drug-Eluting Stents | *Sirolimus/aa [Analogs & Derivatives] | Aged | Antineoplastic Agents, Phytogenic/pd [Pharmacology] | Coronary Angiography | Coronary Artery Disease/ra [Radiography] | Coronary Restenosis/pc [Prevention & Control] | Female | Follow-Up Studies | Humans | Immunosuppressive Agents/pd [Pharmacology] | Male | Middle Aged | Paclitaxel | Prosthesis Design | Retrospective Studies | Sirolimus/pd [Pharmacology] | Treatment OutcomeYear: 2012Local holdings: Available online from MWHC library: 1995 - present, Available in print through MWHC library: 1999 - 2006ISSN:
  • 0002-9149
Name of journal: The American journal of cardiologyAbstract: Data from randomized clinical trials have shown the safety and efficacy of the XIENCE V in selected populations. However, limited data are available comparing the XIENCE V to the first-generation CYPHER sirolimus-eluting stent. This study aimed to assess the long-term safety and clinical efficacy of the XIENCE V everolimus-eluting stent compared to first-generation stents in an unselected patient population. This retrospective analysis included 6,069 patients treated with CYPHER, TAXUS, and XIENCE stents from 2003 to 2009 at our institution. The patients were followed up for >=1 year after the index procedure. The baseline characteristics were generally comparable among the 3 groups, with the exception of a significantly greater prevalence of diabetes mellitus, systemic hypertension, and a history of angioplasty and coronary bypass surgery among the XIENCE patients. The XIENCE patients also had a twofold greater rate of type C lesions. One-year follow-up data were available for 82% of the patients. The 1-year major adverse cardiovascular events rate was 9.3% for the XIENCE stent versus 9.8% for the CYPHER stent and 11.5% for the TAXUS stent (p = 0.11). Mortality was lower in the XIENCE group than in the CYPHER and TAXUS groups (3.6% vs 4.9% vs 7.2%, respectively, p <0.001), and target lesion revascularization was similar (5.9% vs 5.2% vs 5.6%, respectively; p = 0.34). Stent thrombosis was lower in the XIENCE patients (0.2% vs 1.2% vs 0.7%, p = 0.007). In conclusion, in a contemporary United States clinical practice with an unselected patient population, use of the XIENCE V stent was associated with an improved safety profile and reduction of all-cause mortality and stent thrombosis compared to first-generation drug-eluting stents. The XIENCE V failed to demonstrate superiority for overall major adverse cardiovascular events, Q-wave myocardial infarction, and revascularization rates. Copyright 2012 Elsevier Inc. All rights reserved.All authors: Barbash IM, Ben-Dor I, Dvir D, Kent KM, Maluenda G, Pichard AD, Satler LF, Suddath WO, Torguson R, Waksman R, Xue ZFiscal year: FY2012Digital Object Identifier: Date added to catalog: 2013-09-17
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 22341925 Available 22341925

Available online from MWHC library: 1995 - present, Available in print through MWHC library: 1999 - 2006

Data from randomized clinical trials have shown the safety and efficacy of the XIENCE V in selected populations. However, limited data are available comparing the XIENCE V to the first-generation CYPHER sirolimus-eluting stent. This study aimed to assess the long-term safety and clinical efficacy of the XIENCE V everolimus-eluting stent compared to first-generation stents in an unselected patient population. This retrospective analysis included 6,069 patients treated with CYPHER, TAXUS, and XIENCE stents from 2003 to 2009 at our institution. The patients were followed up for >=1 year after the index procedure. The baseline characteristics were generally comparable among the 3 groups, with the exception of a significantly greater prevalence of diabetes mellitus, systemic hypertension, and a history of angioplasty and coronary bypass surgery among the XIENCE patients. The XIENCE patients also had a twofold greater rate of type C lesions. One-year follow-up data were available for 82% of the patients. The 1-year major adverse cardiovascular events rate was 9.3% for the XIENCE stent versus 9.8% for the CYPHER stent and 11.5% for the TAXUS stent (p = 0.11). Mortality was lower in the XIENCE group than in the CYPHER and TAXUS groups (3.6% vs 4.9% vs 7.2%, respectively, p <0.001), and target lesion revascularization was similar (5.9% vs 5.2% vs 5.6%, respectively; p = 0.34). Stent thrombosis was lower in the XIENCE patients (0.2% vs 1.2% vs 0.7%, p = 0.007). In conclusion, in a contemporary United States clinical practice with an unselected patient population, use of the XIENCE V stent was associated with an improved safety profile and reduction of all-cause mortality and stent thrombosis compared to first-generation drug-eluting stents. The XIENCE V failed to demonstrate superiority for overall major adverse cardiovascular events, Q-wave myocardial infarction, and revascularization rates. Copyright 2012 Elsevier Inc. All rights reserved.

English