Anatomical Characteristics Associated With Hypoattenuated Leaflet Thickening in Low-Risk Patients Undergoing Transcatheter Aortic Valve Replacement.

MedStar author(s):
Citation: Cardiovascular Revascularization Medicine. 27:1-6, 2021 06.PMID: 33129688Institution: MedStar Health Research Institute | MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: *Aortic Valve Stenosis | *Heart Valve Prosthesis | *Transcatheter Aortic Valve Replacement | Aortic Valve Stenosis/dg [Diagnostic Imaging] | Aortic Valve Stenosis/su [Surgery] | Aortic Valve/dg [Diagnostic Imaging] | Aortic Valve/su [Surgery] | Humans | Prospective Studies | Prosthesis Design | Transcatheter Aortic Valve Replacement/ae [Adverse Effects] | Treatment OutcomeYear: 2021Local holdings: Available in print through MWHC library: 2002 - presentISSN:
  • 1878-0938
Name of journal: Cardiovascular revascularization medicine : including molecular interventionsAbstract: BACKGROUND/PURPOSE: This sub-analysis of the prospective Low Risk TAVR (LRT) trial determined anatomical characteristics associated with hypoattenuated leaflet thickening (HALT), which may contribute to early transcatheter heart valve (THV) degeneration.CONCLUSIONS: This study did not find anatomical or THV implantation characteristics that predicted the development of HALT at 30 days. This study cannot exclude subtle effects or interaction between factors because of the small number of events.METHODS/MATERIALS: The LRT trial enrolled 200 low-risk patients between February 2016 and February 2018. All subjects underwent baseline and 30-day CT studies, analyzed by an independent core laboratory. Additional measurements, namely THV expansion, eccentricity, depth, and commissural alignment, were made by consensus of three independent readers. HALT was observed only in the Sapien 3 THV, so Evolut valves were excluded from this analysis.RESULTS: In the LRT trial, 177 subjects received Sapien 3 THVs, of whom 167 (94.3%) had interpretable 30-day CTs and were eligible for this analysis. Twenty-six subjects had HALT (15.6%). Baseline characteristics were similar between groups. There was no difference in THV size implanted and baseline aortic-root geometry between groups. In patients who developed HALT, THV implantation depth was shallower than in patients who did not develop HALT (2.6 +/- 1.1 mm HALT versus 3.3 +/- 1.8 mm no-HALT, p = 0.03). There were more patients in the HALT group with commissural malalignment (40% vs. 28%; p = 0.25), but this did not reach statistical significance. In a univariable regression model, no predetermined variables were shown to independently predict the development of HALT.SUMMARY: This sub-analysis of the prospective Low Risk TAVR trial found that hypoattenuated leaflet thickening (HALT) was associated with shallower transcatheter heart valve implantation. No predictors of HALT were found in a univariable regression analysis. Copyright (c) 2020. Published by Elsevier Inc.All authors: Asch FM, Ben-Dor I, Bilfinger T, Buchanan S, Buchbinder M, Butzel D, Chezar-Azerrad C, Ehsan A, Garcia-Garcia HM, Garrett R, Goncalves J, Gordon P, Greenspun B, Gupta N, Hahn C, Hanna N, Hashim H, Khan JM, Kolm P, Levitt R, Medvedofsky D, Parikh P, Rodriguez-Weisson FJ, Rogers T, Satler LF, Shults C, Torguson R, Waksman R, Weissman G, Wilson SR, Zhang COriginally published: Cardiovascular Revascularization Medicine. 2020 Sep 25Fiscal year: FY2021Fiscal year of original publication: FY2021Digital Object Identifier: Date added to catalog: 2020-12-29
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 33129688 Available 33129688

Available in print through MWHC library: 2002 - present

BACKGROUND/PURPOSE: This sub-analysis of the prospective Low Risk TAVR (LRT) trial determined anatomical characteristics associated with hypoattenuated leaflet thickening (HALT), which may contribute to early transcatheter heart valve (THV) degeneration.

CONCLUSIONS: This study did not find anatomical or THV implantation characteristics that predicted the development of HALT at 30 days. This study cannot exclude subtle effects or interaction between factors because of the small number of events.

METHODS/MATERIALS: The LRT trial enrolled 200 low-risk patients between February 2016 and February 2018. All subjects underwent baseline and 30-day CT studies, analyzed by an independent core laboratory. Additional measurements, namely THV expansion, eccentricity, depth, and commissural alignment, were made by consensus of three independent readers. HALT was observed only in the Sapien 3 THV, so Evolut valves were excluded from this analysis.

RESULTS: In the LRT trial, 177 subjects received Sapien 3 THVs, of whom 167 (94.3%) had interpretable 30-day CTs and were eligible for this analysis. Twenty-six subjects had HALT (15.6%). Baseline characteristics were similar between groups. There was no difference in THV size implanted and baseline aortic-root geometry between groups. In patients who developed HALT, THV implantation depth was shallower than in patients who did not develop HALT (2.6 +/- 1.1 mm HALT versus 3.3 +/- 1.8 mm no-HALT, p = 0.03). There were more patients in the HALT group with commissural malalignment (40% vs. 28%; p = 0.25), but this did not reach statistical significance. In a univariable regression model, no predetermined variables were shown to independently predict the development of HALT.

SUMMARY: This sub-analysis of the prospective Low Risk TAVR trial found that hypoattenuated leaflet thickening (HALT) was associated with shallower transcatheter heart valve implantation. No predictors of HALT were found in a univariable regression analysis. Copyright (c) 2020. Published by Elsevier Inc.