Your search returned 16 results. Subscribe to this search

|
1. Ultrathin Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization: 3-Year Outcomes From the Randomized BIOFLOW V Trial

by Garcia-Garcia, Hector M; Waksman, Ron.

Published: 2020; ; ; Citation: Jacc: Cardiovascular Interventions. 13(11):1343-1353, 2020 06 08.; .Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Bennett J; BIOFLOW V Investigators; Cutlip DE; Doros G; Garcia-Garcia HM; Gharib EG; Kandzari DE; Koolen JJ; Roguin A; Waksman R.UI/PMID: 32499026.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1016/j.jcin.2020.02.019https://dx.doi.org/10.1016/j.jcin.2020.02.019 (Click here) | (Click here)
2. Mechanism of Drug-Eluting Absorbable Metal Scaffold Restenosis: A Serial Optical Coherence Tomography Study

by Garcia-Garcia, Hector M.

Published: 2020; ; ; Citation: Circulation: Cardiovascular Interventions. 13(3):e008657, 2020 03.; .Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Byrne R; Garcia-Garcia HM; Haude M; Joner M; Koolen J; Landmesser U; Losdat S; Otsuka T; Raber L; Rai H; Ueki Y; Windecker S.UI/PMID: 32093514.Digital Object Identifier: https://dx.doi.org/10.1161/CIRCINTERVENTIONS.119.008657https://dx.doi.org/10.1161/CIRCINTERVENTIONS.119.008657 (Click here) | (Click here)
3. The Orsiro ultrathin, bioresorbable-polymer sirolimus-eluting stent: A review of current evidence. [Review]

by Case, Brian C; Forrestal, Brian J; Garcia-Garcia, Hector M; Waksman, Ron; Yerasi, Charan.

Published: 2020; ; ; Citation: Cardiovascular Revascularization Medicine. 21(4):540-548, 2020 04.; .Institution: MedStar Heart & Vascular Instituteon.Publication: Journal Article.Article type: Journal Article; Review.Full author list: Case BC; Forrestal BJ; Garcia-Garcia HM; Waksman R; Yerasi C.UI/PMID: 31952919.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1016/j.carrev.2019.12.039https://dx.doi.org/10.1016/j.carrev.2019.12.039 (Click here) | (Click here)
4. Second-Generation Drug-Eluting Resorbable Magnesium Scaffold: Review of the Clinical Evidence. [Review]

by Garcia-Garcia, Hector M; Hideo-Kajita, Alexandre; Ozaki, Yuichi; Shlofmitz, Evan; Waksman, Ron.

Published: ; 2020; ; Citation: ; Cardiovascular Revascularization Medicine. 21(1):127-136, 2020 01..Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article; Review.Full author list: Garcia-Garcia HM; Hideo-Kajita A; Ozaki Y; Shlofmitz E; Waksman R.UI/PMID: 31662277.Digital Object Identifier: https://dx.doi.org/10.1016/j.carrev.2019.10.012 (Click here)
5. First Report of Edge Vascular Response at 12Months of Magmaris, A Second-Generation Drug-Eluting Resorbable Magnesium Scaffold, Assessed by Grayscale Intravascular Ultrasound, Virtual Histology, and Optical Coherence Tomography. A Biosolve-II Trial Sub-Study

by Azizi, Viana; Dan, Kazuhiro; Garcia-Garcia, Hector M; Hideo-Kajita, Alexandre; Kuku, Kayode; Ozaki, Yuichi; Waksman, Ron.

Published: ; 2019; Citation: ; Cardiovascular Revascularization Medicine. 20(5):392-398, 2019 05..Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Abizaid A; Azizi V; Christiansen EH; Dan K; Eeckhout E; Escaned J; Garcia-Garcia HM; Haude M; Hideo-Kajita A; Ince H; Joner M; Kaiser C; Koolen J; Kuku KO; Lemos PA; Neumann FJ; Ozaki Y; Teik LS; Toelg R; von Birgelen C; Waksman R; Wijns W.UI/PMID: 31079817.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1016/j.carrev.2019.02.019 (Click here)
6. Serial 3-Dimensional Optical Coherence Tomography Assessment of Jailed Side-Branch by Second-Generation Drug-Eluting Absorbable Metal Scaffold (from the BIOSOLVE-II Trial)

by Garcia-Garcia, Hector M; Hideo-Kajita, Alexandre; Kuku, Kayode; Ozaki, Yuichi; Waksman, Ron.

Published: 2019; Citation: American Journal of Cardiology. 123(7):1044-1051, 2019 04 01.; .Institution: MedStar Heart & Vascular Institute; MedStar Washington Hospital Center.Publication: Journal Article.Article type: Journal Article.Full author list: Abizaid A; Christiansen EH; Escaned J; Garcia-Garcia HM; Haude M; Hideo-Kajita A; Ince H; Kuku KO; Lemos PA; Ozaki Y; Tolg R; von Birgelen C; Waksman R; Wijns W.UI/PMID: 30683424.Digital Object Identifier: https://dx.doi.org/10.1016/j.amjcard.2018.12.029 (Click here)
7. Impact of procedural characteristics on coronary vessel wall healing following implantation of second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary artery lesions: an optical coherence tomography analysis

by Garcia-Garcia, Hector M; Hideo-Kajita, Alexandre; Kuku, Kayode; Ozaki, Yuichi; Waksman, Ron.

Published: 2019; ; ; Citation: European heart journal cardiovascular Imaging. 20(8):916-924, 2019 Aug 01.; .Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Abizaid A; Christiansen EH; Dijkstra J; Escaned J; Garcia-Garcia HM; Haude M; Hideo-Kajita A; Ince H; Kuku KO; Lemos PA; Ozaki Y; Tolg R; von Birgelen C; Waksman R; Wijns W.UI/PMID: 30590578.Digital Object Identifier: https://dx.doi.org/10.1093/ehjci/jey210https://dx.doi.org/10.1093/ehjci/jey210 (Click here) | (Click here)
8. Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients

by Garcia-Garcia, Hector M; Waksman, Ron.

Published: 2018; Citation: Circulation: Cardiovascular Interventions. 11(10):e007331, 2018 Oct..Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Bennett J; Cutlip DE; Doros G; Garcia-Garcia HM; Gharib EG; Kandzari DE; Koolen JJ; Marcusohn E; Massaro JM; Roguin A; Waksman R.UI/PMID: 30354631.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1161/CIRCINTERVENTIONS.118.007331 (Click here)
9. Safety and clinical performance of a drug eluting absorbable metal scaffold in the treatment of subjects with de novo lesions in native coronary arteries: Pooled 12-month outcomes of BIOSOLVE-II and BIOSOLVE-III

by Garcia-Garcia, Hector M; Waksman, Ron.

Published: 2018; Citation: Catheterization & Cardiovascular Interventions. 92(7):E502-E511, 2018 Dec 01..Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Abizaid A; Alves Lemos P; Barbato E; BIOSOLVE-II and III investigators; Christiansen EH; Garcia-Garcia HM; Haude M; Ince H; Kische S; Tolg R; Van Mieghem NM; Verheye S; von Birgelen C; Waksman R.UI/PMID: 30079472.Digital Object Identifier: https://dx.doi.org/10.1002/ccd.27680 (Click here)
10. Scaffold thrombosis following implantation of the ABSORB BVS in routine clinical practice: Insight into possible mechanisms from optical coherence tomography

by Kajita, Alexandre H; Garcia-Garcia, Hector M.

Published: 2018Citation: Catheterization & Cardiovascular Interventions. 92(2):E106-E114, 2018 08 01..Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Kraak RP; Kajita AH; Garcia-Garcia HM; Henriques JPS; Piek JJ; Arkenbout EK; van der Schaaf RJ; Tijssen JGP; de Winter RJ; Wykrzykowska JJ.UI/PMID: 29332307.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1002/ccd.27475 (Click here)
11. In vivo serial invasive imaging of the second-generation drug-eluting absorbable metal scaffold (Magmaris - DREAMS 2G) in de novo coronary lesions: Insights from the BIOSOLVE-II First-In-Man Trial

by Garcia-Garcia, Hector M; Haude, Michael; Kuku, Kayode; Hideo-Kajita, Alexandre; Waksman, Ron.

Published: 2018Citation: ; International Journal of Cardiology. 255:22-28, 2018 Mar 15..Institution: MedStar Heart & Vascular Instituteon.Publication: Journal Article.Article type: Journal Article.Full author list: Garcia-Garcia HM; Haude M; Kuku K; Hideo-Kajita A; Ince H; Abizaid A; Tolg R; Lemos PA; von Birgelen C; Christiansen EH; Wijns W; Escaned J; Dijkstra J; Waksman R.UI/PMID: 29292064.Digital Object Identifier: https://dx.doi.org/10.1016/j.ijcard.2017.12.053 (Click here)
12. Coronary Artery Aneurysm With Thrombosis After Implantation of a Bioresorbable Coronary Artery Scaffold

by Soud, Mohamad; Garcia-Garcia, Hector M.

Published: 2017Citation: Jacc: Cardiovascular Interventions. 10(18):e173-e174, 2017 Sep 25.Institution: MedStar Washington Hospital Center; MedStar Heart & Vascular Institute.Department: Medicine/Internal Medicine.Publication: Journal Article.Article type: Journal Article.Full author list: Hemetsberger R; Gurocak O; Soud M; Garcia-Garcia HM; Weber-Albers J; Nef H; Mollmann H.UI/PMID: 28935086.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1016/j.jcin.2017.07.041 (Click here)
13. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial

by Garcia-Garcia, Hector M; Waksman, Ron.

Published: 2017Citation: ; Lancet. 390(10105):1843-1852, 2017 Oct 21..Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Kandzari DE; Mauri L; Koolen JJ; Massaro JM; Doros G; Garcia-Garcia HM; Bennett J; Roguin A; Gharib EG; Cutlip DE; Waksman R; BIOFLOW V Investigators.UI/PMID: 28851504.Digital Object Identifier: https://dx.doi.org/10.1016/S0140-6736(17)32249-3 (Click here)
14. Letter by Muntane-Carol et al Regarding Article, "Bioresorbable Vascular Scaffolds for the Treatment of Chronic Total Occlusions: An International Multicenter Registry"

by Hideo-Kajita, Alexandre; Garcia-Garcia, Hector M.

Published: 2017Citation: Circulation: Cardiovascular Interventions. 10(6):e005208, 2017 Jun.Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Letter.Full author list: Muntane-Carol G; Hideo-Kajita A; Garcia-Garcia HM.UI/PMID: 28625965.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1161/CIRCINTERVENTIONS.117.005208 (Click here)
15. Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial

by Garcia-Garcia, Hector M; Waksman, Ron.

Published: 2016Citation: European Heart Journal. 37(35):2701-9, 2016 Sep 14.Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Haude M; Ince H; Abizaid A; Toelg R; Lemos PA; von Birgelen C; Christiansen EH; Wijns W; Neumann FJ; Kaiser C; Eeckhout E; Lim ST; Escaned J; Onuma Y; Garcia-Garcia HM; Waksman R.UI/PMID: 27190094.Digital Object Identifier: https://dx.doi.org/10.1093/eurheartj/ehw196 (Click here)
16. Role of invasive imaging in acute and long-term assessment of bioresorbable scaffold technology

by Garcia-Garcia, Hector M.

Published: 2016Citation: Catheterization & Cardiovascular Interventions. 88(S1):38-53, 2016 Nov.Institution: MedStar Heart & Vascular Institute.Publication: Journal Article.Article type: Journal Article.Full author list: Chamie D; Garcia-Garcia H; Costa RA; Onuma Y; Abizaid A; Serruys PW.UI/PMID: 27797463.Online Access: Click here to access online Digital Object Identifier: https://dx.doi.org/10.1002/ccd.26815 (Click here)

Powered by Koha