000 | 03595nam a22005657a 4500 | ||
---|---|---|---|
008 | 180508s20182018 xxu||||| |||| 00| 0 eng d | ||
022 | _a1522-1946 | ||
024 | _a10.1002/ccd.27623 [doi] | ||
040 | _aOvid MEDLINE(R) | ||
099 | _a29602215 | ||
245 | _aReduction of catheter kinks and knots via radial approach. | ||
251 | _aCatheterization & Cardiovascular Interventions. 92(6):1141-1146, 2018 11 15. | ||
252 | _aCatheter Cardiovasc Interv. 92(6):1141-1146, 2018 11 15. | ||
253 | _aCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions | ||
260 | _c2018 | ||
260 | _fFY2019 | ||
265 | _sppublish | ||
266 | _d2018-05-08 | ||
269 | _fFY2018 | ||
501 | _aAvailable online from MWHC library: 1996 - present, Available in print through MWHC library: 1996 - 2006 | ||
520 | _aCopyright (c) 2018 Wiley Periodicals, Inc. | ||
520 | _aCoronary angiography and percutaneous coronary intervention using the radial approach are becoming more frequent. Pronounced guide catheter manipulation in cases with tortuous access routes may lead to severe catheter kinking or knotting. The purpose of this review article is to present several techniques to resolve radial access catheter knots and kinks. First, simple maneuvers such as gentle traction, rotation, and guidewire advancement can often resolve minor kinking; however, complex loops and kinks are often not reversible with these simple maneuvers. Second, fixing the distal catheter tip using external compression, encasing the knot with a larger sheath, or untwisting the knot with hydraulic pressure can be useful. Finally, internal fixation by grasping the kinked catheter with a snare introduced via the femoral artery allows both ends of the catheter to be rotated in opposite directions to untwist the catheter for safe removal. | ||
546 | _aEnglish | ||
650 | _a*Cardiac Catheterization/is [Instrumentation] | ||
650 | _a*Cardiac Catheters | ||
650 | _a*Catheterization, Peripheral/mt [Methods] | ||
650 | _a*Coronary Angiography/is [Instrumentation] | ||
650 | _a*Device Removal/mt [Methods] | ||
650 | _a*Equipment Failure | ||
650 | _a*Percutaneous Coronary Intervention/is [Instrumentation] | ||
650 | _a*Radial Artery | ||
650 | _aCardiac Catheterization/ae [Adverse Effects] | ||
650 | _aCatheterization, Peripheral/ae [Adverse Effects] | ||
650 | _aCoronary Angiography/ae [Adverse Effects] | ||
650 | _aEquipment Design | ||
650 | _aHumans | ||
650 | _aPercutaneous Coronary Intervention/ae [Adverse Effects] | ||
650 | _aRadial Artery/dg [Diagnostic Imaging] | ||
651 | _aMedStar Heart & Vascular Institute | ||
657 | _aCase Reports | ||
700 | _aBen-Dor, Itsik | ||
700 | _aRogers, Toby | ||
700 | _aSatler, Lowell F | ||
700 | _aWaksman, Ron | ||
790 | _aBen-Dor I, Rogers T, Satler LF, Waksman R | ||
856 |
_uhttps://dx.doi.org/10.1002/ccd.27623 _zhttps://dx.doi.org/10.1002/ccd.27623 |
||
858 |
_ySatler, Lowell F _yWaksman, Ron _uhttp://orcid.org/0000-0001-6446-2683 _uhttp://orcid.org/0000-0002-4063-9226 _zhttp://orcid.org/0000-0001-6446-2683 _zhttp://orcid.org/0000-0002-4063-9226 _zhttp://orcid.org/0000-0001-6446-2683 _zhttp://orcid.org/0000-0002-4063-9226 |
||
858 |
_ySatler, Lowell F _yWaksman, Ron _uhttp://orcid.org/0000-0001-6446-2683 _uhttp://orcid.org/0000-0002-4063-9226 _zhttp://orcid.org/0000-0001-6446-2683 _zhttp://orcid.org/0000-0002-4063-9226 _zhttp://orcid.org/0000-0001-6446-2683 _zhttp://orcid.org/0000-0002-4063-9226 |
||
942 |
_cART _dArticle |
||
999 |
_c10769 _d10769 |