000 03364nam a22004337a 4500
008 220221s20222022 xxu||||| |||| 00| 0 eng d
024 _a10.2147/COPD.S319511 [doi]
024 _a319511 [pii]
024 _aPMC8747625 [pmc]
040 _aOvid MEDLINE(R)
099 _a35023914
245 _aMeasuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease. [Review]
251 _aInternational Journal of Copd. 17:79-92, 2022.
252 _aInt J Chron Obstruct Pulmon Dis. 17:79-92, 2022.
252 _zInt J Chron Obstruct Pulmon Dis. 17:79-92, 2022.
253 _aInternational journal of chronic obstructive pulmonary disease
260 _c2022
260 _fFY2022
265 _sepublish
266 _d2022-02-21
268 _aInternational Journal of Copd. 17:79-92, 2022.
520 _aDry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)-a potential indicator for effective DPI use in chronic obstructive pulmonary disease (COPD)-are lacking. To evaluate recommended PIF assessment approaches, we reviewed the Instructions for Use of the In-Check TM DIAL and the prescribing information for eight DPIs approved for use in the treatment of COPD in the United States. To evaluate applied PIF assessment approaches, we conducted a PubMed search from inception to August 31, 2021, for reports of clinical and real-life studies where PIF was measured using the In-Check TM DIAL or through a DPI in patients with COPD. Evaluation of collective sources, including 47 applicable studies, showed that instructions related to the positioning of the patient with their DPI, instructions for exhalation before the inhalation maneuver, the inhalation maneuver itself, and post-inhalation breath-hold times varied, and in many instances, appeared vague and/or incomplete. We observed considerable variation in how PIF was measured in clinical and real-life studies, underscoring the need for a standardized method of PIF measurement. Standardization of technique will facilitate comparisons among studies. Based on these findings and our clinical and research experience, we propose specific recommendations for PIF measurement to standardize the process and better ensure accurate and reliable PIF values in clinical trials and in daily clinical practice. Copyright (c) 2022 Ohar et al.
546 _aEnglish
650 _a*Pulmonary Disease, Chronic Obstructive
650 _aAdministration, Inhalation
650 _aDry Powder Inhalers
650 _aHumans
650 _aLung
650 _aPulmonary Disease, Chronic Obstructive/di [Diagnosis]
650 _aPulmonary Disease, Chronic Obstructive/dt [Drug Therapy]
651 _aMedStar Washington Hospital Center
656 _aRespiratory Therapy
657 _aJournal Article
657 _aReview
700 _aDrescher, Gail S
790 _aAnzueto A, Dhand R, Drescher GS, Drummond MB, Ferguson GT, Halpin DMG, Haughney J, Hess MW, Hoy HM, Mahler DA, Ohar JA, Pleasants RA, Price DB, Usmani OS
856 _uhttps://dx.doi.org/10.2147/COPD.S319511
_zhttps://dx.doi.org/10.2147/COPD.S319511
942 _cART
_dArticle
999 _c868
_d868