Early real-world implant experience with a helix-fixation ventricular leadless pacemaker. (Record no. 14205)

MARC details
000 -LEADER
fixed length control field 03452nam a22004217a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240723s20242024 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1383-875X
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1007/s10840-024-01791-1 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 38509402
245 ## - TITLE STATEMENT
Title Early real-world implant experience with a helix-fixation ventricular leadless pacemaker.
251 ## - Source
Source Journal of Interventional Cardiac Electrophysiology. 2024 Mar 20
252 ## - Abbreviated Source
Abbreviated source J Interv Card Electrophysiol. 2024 Mar 20
253 ## - Journal Name
Journal name Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2024
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2024 Mar 20
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status aheadofprint
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Medline status Publisher
266 ## - Date added to catalog
Date added to catalog 2024-07-23
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications. Copyright © 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
520 ## - SUMMARY, ETC.
Abstract METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated.
520 ## - SUMMARY, ETC.
Abstract RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 OMEGA [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Indexing Automated
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN PROCESS -- NOT YET INDEXED
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Washington Hospital Center
656 ## - INDEX TERM--OCCUPATION
Department Electrophysiology
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Eldadah, Zayd
Institution Code MHVI
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Hadadi, Cyrus A
Institution Code MWHC
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Islam, Malick
Institution Code MHVI
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Thomaides, Athanasios
Institution Code MWHC
790 ## - Authors
All authors Nair DG, Exner DV, Reddy VY, Badie N, Ligon D, Miller MA, Lee B, Doty B, Thomaides A, Eldadah Z, Islam M, Hadadi C
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1007/s10840-024-01791-1">https://dx.doi.org/10.1007/s10840-024-01791-1</a>
Public note https://dx.doi.org/10.1007/s10840-024-01791-1
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
              07/23/2024   38509402 38509402 07/23/2024 07/23/2024 Journal Article

Powered by Koha