MARC details
000 -LEADER |
fixed length control field |
03452nam a22004217a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
240723s20242024 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1383-875X |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1007/s10840-024-01791-1 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
38509402 |
245 ## - TITLE STATEMENT |
Title |
Early real-world implant experience with a helix-fixation ventricular leadless pacemaker. |
251 ## - Source |
Source |
Journal of Interventional Cardiac Electrophysiology. 2024 Mar 20 |
252 ## - Abbreviated Source |
Abbreviated source |
J Interv Card Electrophysiol. 2024 Mar 20 |
253 ## - Journal Name |
Journal name |
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2024 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2024 Mar 20 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Medline status |
Publisher |
266 ## - Date added to catalog |
Date added to catalog |
2024-07-23 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications. Copyright © 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 OMEGA [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Indexing |
Automated |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Washington Hospital Center |
656 ## - INDEX TERM--OCCUPATION |
Department |
Electrophysiology |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Eldadah, Zayd |
Institution Code |
MHVI |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Hadadi, Cyrus A |
Institution Code |
MWHC |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Islam, Malick |
Institution Code |
MHVI |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Thomaides, Athanasios |
Institution Code |
MWHC |
790 ## - Authors |
All authors |
Nair DG, Exner DV, Reddy VY, Badie N, Ligon D, Miller MA, Lee B, Doty B, Thomaides A, Eldadah Z, Islam M, Hadadi C |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1007/s10840-024-01791-1">https://dx.doi.org/10.1007/s10840-024-01791-1</a> |
Public note |
https://dx.doi.org/10.1007/s10840-024-01791-1 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |