Implementation of echocardiography core laboratory best practices: a case study of the PARTNER I trial. (Record no. 1544)

MARC details
000 -LEADER
fixed length control field 04463nam a22006257a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130224s20132013 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0894-7317
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 23465887
245 ## - TITLE STATEMENT
Title Implementation of echocardiography core laboratory best practices: a case study of the PARTNER I trial.
251 ## - Source
Source Journal of the American Society of Echocardiography. 26(4):348-358.e3, 2013 Apr.
252 ## - Abbreviated Source
Abbreviated source J Am Soc Echocardiogr. 26(4):348-358.e3, 2013 Apr.
253 ## - Journal Name
Journal name Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2013
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2013
266 ## - Date added to catalog
Date added to catalog 2014-02-24
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 1995 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Multicenter clinical trials use echocardiographic core laboratories to ensure expertise and consistency in the assessment of imaging eligibility criteria, as well as safety and efficacy end points. The aim of this study was to report the real-world implementation of guidelines for best practices in echocardiographic core laboratories, including their feasibility and quality results, in a large, international multicenter trial.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: This real-world echocardiographic core lab experience in the PARTNER I trial demonstrates that a high standard of measurability and reproducibility can result from extensive quality assurance efforts in both image acquisition and analysis. These results and the echocardiographic data reported here provide a reference for future studies of aortic stenosis patients and should encourage the wider use of echocardiography in clinical research. Copyright 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: Processes and procedures were developed to optimize the acquisition and analysis of echocardiograms for the Placement of Aortic Transcatheter Valves (PARTNER) I trial of percutaneous aortic valve replacement for aortic stenosis. Comparison of baseline findings in the operative and nonoperative cohorts and reproducibility analyses were performed.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Echocardiography was performed in 1,055 patients (mean age, 83 years; 54% men) The average peak and mean aortic valve gradients were 73 + 24 and 43 + 15 mm Hg, and the average aortic valve area was 0.64 + 0.20 cm(2). The average ejection fraction was 52 + 13% by visual estimation and 53 + 14% by biplane planimetry. The mean left ventricular mass index was 151 + 42 g/m(2). The inoperable cohort had lower left ventricular mass and mass indexes and tended to have more severe mitral regurgitation. Core lab reproducibility was excellent, with intraclass correlation coefficients ranging from 0.92 to 0.99 and statistics from 0.58 to 0.85 for key variables. The image acquisition quality improvement process brought measurability to >85%, which was maintained for the duration of the study.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve Stenosis/us [Ultrasonography]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Benchmarking
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Echocardiography/st [Standards]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Heart Valve Prosthesis Implantation
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Surgery, Computer-Assisted/st [Standards]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged, 80 and over
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aorta/us [Ultrasonography]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/pp [Physiopathology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Clinical Trials as Topic
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Echocardiography, Doppler
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Feasibility Studies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Female
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Guideline Adherence
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heart Ventricles/us [Ultrasonography]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Hemodynamics
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Image Processing, Computer-Assisted
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Laboratories
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Male
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Practice Guidelines as Topic
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Quality Assurance, Health Care
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Reproducibility of Results
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Clinical Trial
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
657 ## - INDEX TERM--FUNCTION
Medline publication type Multicenter Study
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Weissman, Neil J
790 ## - Authors
All authors Bloomfield G, Davis L, Douglas PS, Dunn G, Hahn RT, Hueter I, Leon MB, Lerakis S, Miller DC, Pibarot P, Siegel R, Smith CR, Stewart WJ, Waugh RA, Weissman NJ
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="http://dx.doi.org/10.1016/j.echo.2013.01.013">http://dx.doi.org/10.1016/j.echo.2013.01.013</a>
Public note http://dx.doi.org/10.1016/j.echo.2013.01.013
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 02/24/2014   23465887 23465887 02/24/2014 02/24/2014 Journal Article

Powered by Koha