MARC details
000 -LEADER |
fixed length control field |
04494nam a22006617a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190108s20192019 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0003-4975 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.athoracsur.2018.11.013 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S0003-4975(18)31795-8 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
30529671 |
245 ## - TITLE STATEMENT |
Title |
Development and Application of a Risk Prediction Model for In-Hospital Stroke After Transcatheter Aortic Valve Replacement - A Report from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. |
251 ## - Source |
Source |
Annals of Thoracic Surgery. 107(4):1097-1103, 2019 04. |
252 ## - Abbreviated Source |
Abbreviated source |
Ann Thorac Surg. 107(4):1097-1103, 2019 04. |
252 ## - Abbreviated Source |
Former abbreviated source |
Ann Thorac Surg. 2018 Dec 07 |
253 ## - Journal Name |
Journal name |
European journal of emergency medicine : official journal of the European Society for Emergency Medicine |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2019 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2019 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2019-01-08 |
268 ## - Previous citation |
-- |
Annals of Thoracic Surgery. 2018 Dec 07 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1995 - present, Available in print through MWHC library:1999-2007 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Stroke is a serious complication following transcatheter aortic valve replacement (TAVR), yet predictive models are not available. A new risk model for in-hospital stroke following TAVR was developed and used to estimate site-specific performance. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: A risk model for in-hospital stroke following TAVR was developed from the STS/ACC TVT Registry and used to estimate site-specific stroke performance. This model can serve as a valuable resource for quality improvement, clinical decision-making, and patient counseling. |
520 ## - SUMMARY, ETC. |
Abstract |
Copyright (c) 2018. Published by Elsevier Inc. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: We included 97,600 TAVR procedures from 521 sites in the STS/ACC Transcatheter Valve Therapy (TVT) Registry from July 2014 through June 2017. Association between baseline covariates and in-hospital stroke was estimated by logistic regression. Discrimination was evaluated by C statistic. Calibration was tested internally via cross validation. Hierarchical modeling was used to estimate risk-adjusted site-specific performance. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Median age was 82 years, 44,926 (46.0%) were female, and 1,839 (1.9%) had in-hospital stroke. Covariates associated with stroke (odds ratio) included transapical access (1.44), access excluding transapical and transfemoral (1.77), prior stroke (1.57), prior TIA (1.50), pre-procedural shock, inotropes or mechanical assist device (1.48), smoking (1.28), porcelain aorta (1.23), peripheral arterial disease (1.21), age per 5 years (1.11), glomerular filtration rate per 5 ml/min (0.97), body surface area per m<sup>2</sup> (0.55 male; 0.43 female), and prior aortic valve (0.78) and non-aortic valvular (0.42) procedures. The C statistic was 0.622. Calibration curves demonstrated agreement between observed and expected stroke rates. Hierarchical modeling showed 10 centers (1.9%) with significantly higher odds ratios for in-hospital stroke than their peers. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Valve Stenosis/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Hospital Mortality |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Registries |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Stroke/ep [Epidemiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Transcatheter Aortic Valve Replacement/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve Stenosis/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Predictive Value of Tests |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prevalence |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Reproducibility of Results |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Assessment |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Management |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Societies, Medical |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Stroke/et [Etiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Thoracic Surgery |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Transcatheter Aortic Valve Replacement/mo [Mortality] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Transcatheter Aortic Valve Replacement/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
United States |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Thourani, Vinod H |
790 ## - Authors |
All authors |
Arnold SV, Bavaria JE, Brennan JM, Carroll EJ, Cohen DJ, Edwards FH, Fitzgerald S, Forcillo J, Grover FL, Holmes DR, Kelly JJ, Mack MJ, O'Brien SM, Peterson ED, Shahian DM, Thourani VH, Vemulapalli S |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.athoracsur.2018.11.013">https://dx.doi.org/10.1016/j.athoracsur.2018.11.013</a> |
Public note |
https://dx.doi.org/10.1016/j.athoracsur.2018.11.013 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |