Assessing precision and accuracy of false-profile hip radiographs. (Record no. 4571)

MARC details
000 -LEADER
fixed length control field 02781nam a22003377a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191010s20192019 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1120-7000
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1177/1120700019877848 [doi]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 31547722
245 ## - TITLE STATEMENT
Title Assessing precision and accuracy of false-profile hip radiographs.
251 ## - Source
Source Hip International. :1120700019877848, 2019 Sep 23
252 ## - Abbreviated Source
Abbreviated source Hip int.. :1120700019877848, 2019 Sep 23
253 ## - Journal Name
Journal name Hip international : the journal of clinical and experimental research on hip pathology and therapy
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2019
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2020
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status aheadofprint
266 ## - Date added to catalog
Date added to catalog 2019-10-10
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: The quality of FP radiographs obtained in the clinical setting may be inconsistent. Standardising FP imaging produces more accurate images. Appropriate FP radiographs should have a distance between hip centres that is approximately 0.5 times the same distance found on an anteroposterior (AP) radiograph.
520 ## - SUMMARY, ETC.
Abstract METHODS: An imaging protocol was developed to obtain FP radiographs. Pelvic rotation was calculated using the described method for FP images obtained in the 3 months prior to and after implementation of this protocol. Student's t-test and variance ratio tests were used to determine differences in mean and variance of pelvic rotation between the 2 cohorts. Pelvic rotation calculation methodology was validated by using fluoroscopic C-arm to obtain AP and rotated images of 10 osteologic pelvises. The ratio of the distance between hip centres of each rotated image and AP image (WP/W) was determined. Intraclass coefficient correlation (ICC) was used to verify the relationship between WP/W and pelvic rotation.
520 ## - SUMMARY, ETC.
Abstract PURPOSE: The purpose of this study was to assess the accuracy and precision of pelvic rotation in existing false-profile (FP) radiographs and to devise a method to improve accuracy and precision of FP radiographs.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Mean WP/W was 0.47 (95% CI, 0.45-0.49). There were significant differences in mean pelvic rotation of the pre-protocol group (47.6degree; 95% CI, 45.6-49.5degree) and the post-protocol group (60.0degree; 95% CI, 58.7-61.3degree, p < 0.0001). Additionally, there was a significantly wider distribution of measurements in the pre-protocol group (SD = 7.9degree) compared to the post-protocol group (SD = 5.7degree, p = 0.0035).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN PROCESS -- NOT YET INDEXED
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Union Memorial Hospital
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Gould, Heath
790 ## - Authors
All authors Gould H, Hu E, Li RT, Liu RW, Neral M, Salata MJ
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1177/1120700019877848">https://dx.doi.org/10.1177/1120700019877848</a>
Public note https://dx.doi.org/10.1177/1120700019877848
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 10/10/2019   31547722 31547722 10/10/2019 10/10/2019 Journal Article

Powered by Koha