245 ## - TITLE STATEMENT |
Title |
Assessing precision and accuracy of false-profile hip radiographs. |
251 ## - Source |
Source |
Hip International. :1120700019877848, 2019 Sep 23 |
252 ## - Abbreviated Source |
Abbreviated source |
Hip int.. :1120700019877848, 2019 Sep 23 |
253 ## - Journal Name |
Journal name |
Hip international : the journal of clinical and experimental research on hip pathology and therapy |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2019 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2020 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
266 ## - Date added to catalog |
Date added to catalog |
2019-10-10 |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: The quality of FP radiographs obtained in the clinical setting may be inconsistent. Standardising FP imaging produces more accurate images. Appropriate FP radiographs should have a distance between hip centres that is approximately 0.5 times the same distance found on an anteroposterior (AP) radiograph. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: An imaging protocol was developed to obtain FP radiographs. Pelvic rotation was calculated using the described method for FP images obtained in the 3 months prior to and after implementation of this protocol. Student's t-test and variance ratio tests were used to determine differences in mean and variance of pelvic rotation between the 2 cohorts. Pelvic rotation calculation methodology was validated by using fluoroscopic C-arm to obtain AP and rotated images of 10 osteologic pelvises. The ratio of the distance between hip centres of each rotated image and AP image (WP/W) was determined. Intraclass coefficient correlation (ICC) was used to verify the relationship between WP/W and pelvic rotation. |
520 ## - SUMMARY, ETC. |
Abstract |
PURPOSE: The purpose of this study was to assess the accuracy and precision of pelvic rotation in existing false-profile (FP) radiographs and to devise a method to improve accuracy and precision of FP radiographs. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Mean WP/W was 0.47 (95% CI, 0.45-0.49). There were significant differences in mean pelvic rotation of the pre-protocol group (47.6degree; 95% CI, 45.6-49.5degree) and the post-protocol group (60.0degree; 95% CI, 58.7-61.3degree, p < 0.0001). Additionally, there was a significantly wider distribution of measurements in the pre-protocol group (SD = 7.9degree) compared to the post-protocol group (SD = 5.7degree, p = 0.0035). |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Union Memorial Hospital |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Gould, Heath |
790 ## - Authors |
All authors |
Gould H, Hu E, Li RT, Liu RW, Neral M, Salata MJ |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1177/1120700019877848">https://dx.doi.org/10.1177/1120700019877848</a> |
Public note |
https://dx.doi.org/10.1177/1120700019877848 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |