Protein biomarkers identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillators: findings from the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD).

MedStar author(s):
Citation: Circulation: Arrhythmia and Electrophysiology. 7(6):1084-91, 2014 Dec.PMID: 25273351Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal Article | Multicenter Study | Observational Study | Research Support, N.I.H., Extramural | Research Support, Non-U.S. Gov'tSubject headings: *Blood Proteins/an [Analysis] | *Death, Sudden, Cardiac/pc [Prevention & Control] | *Defibrillators, Implantable | *Electric Countershock/is [Instrumentation] | *Primary Prevention/is [Instrumentation] | Aged | Biological Markers/bl [Blood] | Chi-Square Distribution | Death, Sudden, Cardiac/et [Etiology] | Female | Humans | Inflammation Mediators/bl [Blood] | Linear Models | Male | Middle Aged | Multivariate Analysis | Myocardium/me [Metabolism] | Natriuretic Peptide, Brain/bl [Blood] | Patient Selection | Predictive Value of Tests | Primary Prevention/mt [Methods] | Proportional Hazards Models | Prospective Studies | Protein Precursors/bl [Blood] | Risk Assessment | Risk Factors | United States/ep [Epidemiology]Local holdings: Available online from MWHC library: 2008 - presentISSN:
  • 1941-3084
Name of journal: Circulation. Arrhythmia and electrophysiologyAbstract: BACKGROUND: Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs.CLINICAL TRIAL REGISTRATION URL: clinicaltrials.gov; Unique Identifier: NCT00733590.Copyright � 2014 American Heart Association, Inc.CONCLUSIONS: An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs.METHODS AND RESULTS: The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-alpha receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD.All authors: Blasco-Colmenares E, Butcher B, Cheng A, Dalal D, Dickfeld T, Eldadah Z, Ellenbogen KA, Guallar E, Marine JE, Norgard S, Spragg DD, Tomaselli GF, Zhang YDigital Object Identifier: Date added to catalog: 2016-01-13
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article Available 25273351

Available online from MWHC library: 2008 - present

BACKGROUND: Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs.

CLINICAL TRIAL REGISTRATION URL: clinicaltrials.gov; Unique Identifier: NCT00733590.Copyright � 2014 American Heart Association, Inc.

CONCLUSIONS: An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs.

METHODS AND RESULTS: The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-alpha receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD.