Name of journal: International wound journalAbstract: Many surgeons use a single table of instruments for both excisional debridement and coverage/closure of infected wounds. This study investigates the effectiveness of a two-table set-up of sterile instruments, in addition to glove exchange, to reduce instrument cross-contamination during these procedures. This is a prospective, single-site, institutional review board-approved observational study of surgical debridements of infected wounds over a 17-month period. Two separate sterile surgical tables were used for each case: Table A for initial wound debridement (debridement set-up) and Table B for wound coverage/closure (clean set-up). Swabs of each table and its respective instruments were taken after debridement but prior to coverage/closure. The primary outcome of interest was bacterial growth at 48 hours. There were 72 surgical cases included in this study. Culture results of Table A demonstrated bacterial growth in 23 of 72 (32%) cases at 48 hours compared with 5of 72 (7%) from Table B (P = .001). These data suggest that there is significant bacterial contamination of surgical instruments used for debridement of infected wounds. Use of a two-table set-up reduced instrument cross-contamination by 78%, suggesting avoidable re-contamination of the wound. Copyright (c) 2021 The Authors. International Wound Journal published by Medicalhelplines.com Inc (3M) and John Wiley & Sons Ltd.All authors: Attinger CE, Carroll AM, Dekker PK, Evans KK, Kim KG, Kim PJ, Phillips BK, Singh B, Steinberg JS, Walters ETFiscal year: FY2021Digital Object Identifier: Date added to catalog: 2021-06-28
Holdings
Item type Current library Collection Call number Status Date due Barcode
Journal Article MedStar Authors Catalog Article 33955150 Available 33955150

Many surgeons use a single table of instruments for both excisional debridement and coverage/closure of infected wounds. This study investigates the effectiveness of a two-table set-up of sterile instruments, in addition to glove exchange, to reduce instrument cross-contamination during these procedures. This is a prospective, single-site, institutional review board-approved observational study of surgical debridements of infected wounds over a 17-month period. Two separate sterile surgical tables were used for each case: Table A for initial wound debridement (debridement set-up) and Table B for wound coverage/closure (clean set-up). Swabs of each table and its respective instruments were taken after debridement but prior to coverage/closure. The primary outcome of interest was bacterial growth at 48 hours. There were 72 surgical cases included in this study. Culture results of Table A demonstrated bacterial growth in 23 of 72 (32%) cases at 48 hours compared with 5of 72 (7%) from Table B (P = .001). These data suggest that there is significant bacterial contamination of surgical instruments used for debridement of infected wounds. Use of a two-table set-up reduced instrument cross-contamination by 78%, suggesting avoidable re-contamination of the wound. Copyright (c) 2021 The Authors. International Wound Journal published by Medicalhelplines.com Inc (3M) and John Wiley & Sons Ltd.

English

Powered by Koha