TY - BOOK AU - Badr, Salem AU - Dvir, Danny AU - Pichard, Augusto D TI - Adenosine-induced temporary block to improve accuracy of ostial coronary stent implantation: adenosine to improve stent implantation accuracy SN - 1522-1946 KW - *Adenosine/ad [Administration & Dosage] KW - *Coronary Stenosis/th [Therapy] KW - *Heart Block KW - *Percutaneous Coronary Intervention/is [Instrumentation] KW - *Stents KW - *Ventricular Function, Left/de [Drug Effects] KW - Adult KW - Coronary Angiography KW - Coronary Stenosis/di [Diagnosis] KW - Coronary Stenosis/pp [Physiopathology] KW - Electrocardiography KW - Female KW - Humans KW - Injections KW - Treatment Outcome KW - Ultrasonography, Interventional KW - Case Reports KW - Journal Article N1 - Available online from MWHC library: 1996 - present, Available in print through MWHC library: 1996 - 2006 N2 - Implantation of coronary stents should be performed with high precision to ensure optimal clinical results. In some clinical conditions, during the cardiac cycle, significant movement of the predeployed stent may impact its implantation accuracy. We describe a case in which a patient had a short ostial left anterior descending artery stenosis and hyperkinetic left ventricle, resulting in significant movement of the stent inside the vessel lumen during the cardiac cycle. Intracoronary adenosine was used to create temporary heart block to enable accurate stent implantation. Copyright 2013 Wiley Periodicals, Inc UR - http://dx.doi.org/10.1002/ccd.24941 ER -