TY - BOOK AU - Joshi, Siddhi AU - Mathur, Deepti AU - Strickberger, Adam S AU - Venkataraman, Ganesh S TI - Comparison of ICD implantation in obese and nonobese patients SN - 0147-8389 KW - *Defibrillators, Implantable/sn [Statistics & Numerical Data] KW - *Heart Failure/mo [Mortality] KW - *Heart Failure/pc [Prevention & Control] KW - *Obesity/ep [Epidemiology] KW - *Postoperative Complications/mo [Mortality] KW - *Prosthesis Implantation/mo [Mortality] KW - Aged KW - Comorbidity KW - District of Columbia/ep [Epidemiology] KW - Female KW - Humans KW - Incidence KW - Male KW - Retrospective Studies KW - Risk Assessment KW - Survival Rate KW - MedStar Heart & Vascular Institute KW - Comparative Study KW - Journal Article N1 - Available online through MWHC library: 2008 - present, Available in print through MWHC library: 1999 - 2006 N2 - BACKGROUND: Implantable defibrillator (ICD) therapy improves mortality in patients at risk for sudden cardiac death. Obese patients pose challenges during ICD implantation and may have an increased risk of procedure-related complications. The comparison of acute procedural success and safety of ICD implantation in obese and nonobese patients has not been previously reported; CONCLUSIONS: Acute success and safety of ICD implantation is similar in both obese and nonobese patients. This finding extended to patients treated with a CRT-ICD and among patients with extreme obesity. Obesity should probably not be a factor in determining whether a patient is a candidate for ICD implantation.Copyright �2013, The Authors. Journal compilation �2013 Wiley Periodicals, Inc; METHODS: A total of 181 patients underwent ICD implantation at a single institution. Obesity was defined as a body mass index (BMI) greater than or equal to 30 kg/m(2) . Acute safety and efficacy data were collected and analyzed from a prospectively maintained database, with retrospective chart review, as required; RESULTS: Among the 181 patients, 58 (32.0%) were obese. Mean BMI was 36.7 +/- 6.3 kg/m(2) among obese patients and was 24.6 +/- 3.1 kg/m(2) among nonobese patients (P < 0.001). Successful ICD implantation occurred in 58 of 58 (100%) obese patients and 122 of 123 (99.2%) nonobese patients (P = 1.0). A complication was observed in three of 58 (5.2%) obese patients and in seven of 123 (5.7%) nonobese patients (P = 1.0). Similarly, there was no difference in acute procedural success and safety in patients receiving a cardiac resynchronization therapy (CRT)-ICD UR - http://dx.doi.org/10.1111/pace.12297 ER -