TY - BOOK AU - Weissman, Neil J TI - CT-Defined Prosthesis-Patient Mismatch Downgrades Frequency and Severity, and Demonstrates No Association With Adverse Outcomes After TAVR SN - 1936-8798 PY - 2017/// KW - *Aortic Valve Stenosis/su [Surgery] KW - *Aortic Valve/su [Surgery] KW - *Heart Valve Prosthesis KW - *Postoperative Complications/dg [Diagnostic Imaging] KW - *Tomography, X-Ray Computed KW - *Transcatheter Aortic Valve Replacement/is [Instrumentation] KW - Aged KW - Aged, 80 and over KW - Aortic Valve Stenosis/dg [Diagnostic Imaging] KW - Aortic Valve Stenosis/mo [Mortality] KW - Aortic Valve Stenosis/pp [Physiopathology] KW - Aortic Valve/dg [Diagnostic Imaging] KW - Aortic Valve/pp [Physiopathology] KW - Area Under Curve KW - Echocardiography, Doppler KW - Female KW - Humans KW - Hypertrophy, Left Ventricular/dg [Diagnostic Imaging] KW - Hypertrophy, Left Ventricular/pp [Physiopathology] KW - Kaplan-Meier Estimate KW - Male KW - Postoperative Complications/mo [Mortality] KW - Postoperative Complications/pc [Prevention & Control] KW - Postoperative Complications/pp [Physiopathology] KW - Predictive Value of Tests KW - Prosthesis Design KW - Registries KW - Reproducibility of Results KW - Risk Assessment KW - Risk Factors KW - ROC Curve KW - Severity of Illness Index KW - Transcatheter Aortic Valve Replacement/ae [Adverse Effects] KW - Transcatheter Aortic Valve Replacement/mo [Mortality] KW - Treatment Outcome KW - MedStar Heart & Vascular Institute KW - Journal Article N1 - Available online through MWHC library: 2008 - present N2 - BACKGROUND: PPM does not predict mortality following transcatheter aortic valve replacement (TAVR). However, it is unknown if the EOAiCT of the left ventricular outflow tract improves risk stratification; CONCLUSIONS: EOAiCT downgrades frequency and severity of PPM in patients after TAVR, and was not associated with mortality 1 year after TAVR. EOAiTTE, but not EOAiCT, was associated with less left ventricular mass regression. Copyright (c) 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved; METHODS: A total of 765 TAVR patients from the PARTNER II (Placement of Aortic Transcatheter Valves II) trial S3i cohort were evaluated. EOAi was calculated using the continuity equation, and the left ventricular outflow tract area was derived from baseline computed tomography. Traditional echocardiographic categories defined PPM: absent (>0.85 cm2/m2), moderate (>=0.65 and <=0.85 cm2/m2), or severe (<=0.65 cm2/m2). Correlation of EOAiCT and EOAiTTE to 1-year outcomes was performed; OBJECTIVES: This study sought to determine if indexed effective orifice area (EOAi), using left ventricular outflow tract measured from computed tomography (EOAiCT), reclassified prosthesis-patient mismatch (PPM) compared with conventional echocardiogram-defined measurements (EOAiTTE); RESULTS: The incidence of PPM was 24% with EOACT compared with 45% with EOAiTTE. Only 6% of PPM was graded severe by EOAiCT compared with 9% by EOAiTTE. EOAiTTE, but not EOAiCT, defined PPM showed association with reduced left ventricular mass regression (p = 0.03 vs. p = 0.52). There was no association between PPM and death or rehospitalization at 1 year with either modality. EOACT was associated with minor stroke at 1 year (log-rank p = 0.04), and EOAiTTE with stroke/transient ischemic attack (log-rank p = 0.030). Furthermore, when subjects with mild or greater paravalvular regurgitation were excluded, the presence of PPM did not show association with any outcome UR - https://dx.doi.org/10.1016/j.jcin.2017.05.031 ER -