MARC details
000 -LEADER |
fixed length control field |
02650nam a22003857a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190823s20192019 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0894-9115 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
00002060-201908000-00005 [pii] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1097/PHM.0000000000001167 [doi] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
31318746 |
245 ## - TITLE STATEMENT |
Title |
Assessing the Accuracy of Ultrasound-Guided Needle Placement in Sacroiliac Joint Injections. |
251 ## - Source |
Source |
American Journal of Physical Medicine & Rehabilitation. 98(8):666-670, 2019 Aug. |
252 ## - Abbreviated Source |
Abbreviated source |
Am J Phys Med Rehabil. 98(8):666-670, 2019 Aug. |
253 ## - Journal Name |
Journal name |
American journal of physical medicine & rehabilitation |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2019 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2020 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2019-08-23 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1996 - present |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: Ultrasound-guided injection of the sacroiliac joint is successful and accurate upon confirmation of fluoroscopic arthrogram and should be used as an imaging modality for needle guidance. |
520 ## - SUMMARY, ETC. |
Abstract |
DESIGN: Institutional review board approval was gained for a prospective cohort study of 50 patients (N = 50). Study patients who were referred for sacroiliac joint injections for sacroiliac joint mediate pain and met inclusion/exclusion criteria were enrolled in the study. Each patient underwent needle placement with ultrasound guidance in the procedure suite. After the needle was placed with the ultrasound guidance, fluoroscopy was used to confirm correct placement via contrast injection confirming a sacroiliac joint arthrogram. The arthrogram was confirmed via the performing physician and radiologist. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVE: The aim of the study was to assess the accuracy of ultrasound-guided needle placement for sacroiliac joint injections. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: The placement of the needle with ultrasound guidance into the sacroiliac joint was confirmed successful in 96% (48/50) patients by fluoroscopic arthrogram. The two patients with unsuccessful arthrograms after initial placement of the needle with ultrasound were morbidly obese. There was intravascular uptake during the arthrogram of one patient who had a successful arthrogram. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar National Rehabilitation Network |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
De Luigi, Arthur Jason |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Mathur, Rajat |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Yokel, Nathan |
790 ## - Authors |
All authors |
De Luigi AJ, Mathur R, Saini A, Saini V, Yokel N |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1097/PHM.0000000000001167">https://dx.doi.org/10.1097/PHM.0000000000001167</a> |
Public note |
https://dx.doi.org/10.1097/PHM.0000000000001167 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |