Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry. (Record no. 6701)

MARC details
000 -LEADER
fixed length control field 04618nam a22005777a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210726s20212021 xxu||||| |||| 00| 0 eng d
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.jcin.2021.03.069 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S1936-8798(21)00674-9 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 34238557
245 ## - TITLE STATEMENT
Title Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry.
251 ## - Source
Source Jacc: Cardiovascular Interventions. 14(13):1466-1477, 2021 07 12.
252 ## - Abbreviated Source
Abbreviated source JACC Cardiovasc Interv. 14(13):1466-1477, 2021 07 12.
252 ## - Abbreviated Source
Former abbreviated source JACC Cardiovasc Interv. 14(13):1466-1477, 2021 Jul 12.
253 ## - Journal Name
Journal name JACC. Cardiovascular interventions
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2021
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2022
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2021 Jul 12
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2021-07-26
268 ## - Previous citation
-- Jacc: Cardiovascular Interventions. 14(13):1466-1477, 2021 Jul 12.
269 ## - Original dates
Original fiscal year FY2022
501 ## - WITH NOTE
Local holdings Available online through MWHC library: 2008 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. Copyright (c) 2021 The Authors. Published by Elsevier Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <=0.85 cm2/m2 (<=0.70 if obese: body mass index >=30 kg/m2) and severe if EOAi <=0.65 cm2/m2 (<=0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR).
520 ## - SUMMARY, ETC.
Abstract RESULTS: The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve Stenosis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Heart Valve Prosthesis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Heart Valve Prosthesis Implantation
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Transcatheter Aortic Valve Replacement
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heart Valve Prosthesis Implantation/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prosthesis Design
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Registries
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Risk Factors
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Treatment Outcome
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Weissman, Neil J
790 ## - Authors
All authors Abbas AE, Alu M, Annabi MS, Bax J, Beaudoin J, Bernier M, Blanke P, Clavel MA, Dahou A, Douglas P, Guzzetti E, Hahn RT, Herrmann HC, Jaber W, Khalique OK, Kodali S, Leipsic J, Leon M, Mack MJ, Pibarot P, Rogers E, Salaun E, Ternacle J, Thourani VH, Weissman NJ, Xu K
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.jcin.2021.03.069">https://dx.doi.org/10.1016/j.jcin.2021.03.069</a>
Public note https://dx.doi.org/10.1016/j.jcin.2021.03.069
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 07/26/2021   34238557 34238557 07/26/2021 07/26/2021 Journal Article

Powered by Koha