MARC details
000 -LEADER |
fixed length control field |
04618nam a22005777a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
210726s20212021 xxu||||| |||| 00| 0 eng d |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.jcin.2021.03.069 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S1936-8798(21)00674-9 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
34238557 |
245 ## - TITLE STATEMENT |
Title |
Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry. |
251 ## - Source |
Source |
Jacc: Cardiovascular Interventions. 14(13):1466-1477, 2021 07 12. |
252 ## - Abbreviated Source |
Abbreviated source |
JACC Cardiovasc Interv. 14(13):1466-1477, 2021 07 12. |
252 ## - Abbreviated Source |
Former abbreviated source |
JACC Cardiovasc Interv. 14(13):1466-1477, 2021 Jul 12. |
253 ## - Journal Name |
Journal name |
JACC. Cardiovascular interventions |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2021 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2021 Jul 12 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2021-07-26 |
268 ## - Previous citation |
-- |
Jacc: Cardiovascular Interventions. 14(13):1466-1477, 2021 Jul 12. |
269 ## - Original dates |
Original fiscal year |
FY2022 |
501 ## - WITH NOTE |
Local holdings |
Available online through MWHC library: 2008 - present |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. Copyright (c) 2021 The Authors. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <=0.85 cm2/m2 (<=0.70 if obese: body mass index >=30 kg/m2) and severe if EOAi <=0.65 cm2/m2 (<=0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Valve Stenosis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Heart Valve Prosthesis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Heart Valve Prosthesis Implantation |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Transcatheter Aortic Valve Replacement |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve Stenosis/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve Stenosis/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Heart Valve Prosthesis Implantation/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Design |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Registries |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Transcatheter Aortic Valve Replacement/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Treatment Outcome |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Weissman, Neil J |
790 ## - Authors |
All authors |
Abbas AE, Alu M, Annabi MS, Bax J, Beaudoin J, Bernier M, Blanke P, Clavel MA, Dahou A, Douglas P, Guzzetti E, Hahn RT, Herrmann HC, Jaber W, Khalique OK, Kodali S, Leipsic J, Leon M, Mack MJ, Pibarot P, Rogers E, Salaun E, Ternacle J, Thourani VH, Weissman NJ, Xu K |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.jcin.2021.03.069">https://dx.doi.org/10.1016/j.jcin.2021.03.069</a> |
Public note |
https://dx.doi.org/10.1016/j.jcin.2021.03.069 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |