Hemodynamics and Subclinical Leaflet Thrombosis in Low-Risk Patients Undergoing Transcatheter Aortic Valve Replacement.

Hemodynamics and Subclinical Leaflet Thrombosis in Low-Risk Patients Undergoing Transcatheter Aortic Valve Replacement. - 2019

BACKGROUND: This analysis evaluated echocardiographic predictors of hypoattenuated leaflet thickening (HALT) in low-risk patients undergoing transcatheter aortic valve replacement and assessed 1-year clinical and hemodynamic consequences. HALT by computed tomography may be associated with early valve degeneration and increased neurological events. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02628899. CONCLUSIONS: There were no early hemodynamic predictors of HALT. At 30 days, patients with HALT had worse valve hemodynamics than those without HALT, but hemodynamic and clinical outcomes at 1 year were similar. METHODS: Echocardiograms were performed at baseline, discharge, 30 days, and 1 year post-procedure. Four-dimensional contrast-enhanced computed tomography assessed HALT at 30 days. Independent core laboratories analyzed images. Doppler hemodynamic parameters were tested in a univariable regression model to identify HALT predictors. One-year clinical and hemodynamic outcomes were compared between HALT (+) and (-) patients. RESULTS: Analysis included 170 patients with Sapien 3 valves and diagnostic 30-day computed tomographies, of whom 27 (16%) had HALT. Baseline characteristics were similar between groups. After transcatheter aortic valve replacement, aortic flow was nonsignificantly reduced in patients who developed HALT. Regression analysis did not show significant association between baseline or discharge valve hemodynamics and development of HALT at 30 days. Patients with HALT had smaller aortic valve areas (1.4+/-0.4 versus 1.7+/-0.5 cm2; P=0.018) and Doppler velocity index (0.4+/-0.1 versus 0.5+/-0.1; P=0.003) than those without HALT at 30 days but not at 1 year. There was no difference in aortic mean gradient at 30 days. There was no difference between the groups in New York Heart Association class, 6-minute walk distance, and mortality at 1 year.


English

1941-9651

10.1161/CIRCIMAGING.119.009608 [doi]


*Aortic Valve Stenosis/su [Surgery]
*Aortic Valve/su [Surgery]
*Heart Valve Prosthesis
*Hemodynamics
*Thrombosis/et [Etiology]
*Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
*Transcatheter Aortic Valve Replacement/is [Instrumentation]
Aged
Aged, 80 and over
Aortic Valve Stenosis/dg [Diagnostic Imaging]
Aortic Valve Stenosis/pp [Physiopathology]
Aortic Valve/dg [Diagnostic Imaging]
Aortic Valve/pp [Physiopathology]
Echocardiography, Doppler
Female
Four-Dimensional Computed Tomography
Humans
Male
Predictive Value of Tests
Prospective Studies
Prosthesis Failure
Risk Assessment
Risk Factors
Thrombosis/dg [Diagnostic Imaging]
Thrombosis/pp [Physiopathology]
Time Factors
Treatment Outcome
United States


MedStar Heart & Vascular Institute


Journal Article

Powered by Koha