Computer Simulated Enhancement and Planning, Robotics and Navigation With Patient Specific Implants and 3-D Printed Cages. (Record no. 11167)

MARC details
000 -LEADER
fixed length control field 03816nam a22004577a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220511s20222022 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 2192-5682
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1177/21925682211003554 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code PMC8998477 [pmc]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 35393879
245 ## - TITLE STATEMENT
Title Computer Simulated Enhancement and Planning, Robotics and Navigation With Patient Specific Implants and 3-D Printed Cages.
251 ## - Source
Source Global Spine Journal. 12(2_suppl):7S-18S, 2022 Apr.
252 ## - Abbreviated Source
Abbreviated source Global spine j.. 12(2_suppl):7S-18S, 2022 Apr.
253 ## - Journal Name
Journal name Global spine journal
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2022
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2022
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2022 Apr
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2022-05-11
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: This consecutive series of 33 cases demonstrated the utility of measuring the preoperative middle column length in predicting the optimal height of the spacers, intervertebral disks, and posterior vertebral body height simultaneously restoring sagittal and coronal plane alignment.
520 ## - SUMMARY, ETC.
Abstract METHODS: Multiple Observers Measurement Testing. 33 consecutive vertebral levels requiring interbody spacers for multilevel deformities had middle column height pre and post operatively measured by 3 blinded observers. The preoperative and postoperative measurements were compared using a linear regression analysis and Pearson product-moment correlation.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: Pre and postop Measurement Testing. This is a retrospective study of 33 consecutive interbody spacers in 21 patients who underwent pre, intra, and postoperative measurement of the middle column to determine if this would lead to more precise restoration of middle column height and spacer fit. Scaled transparencies of the pre-operative simulation of angular correction and spacer geometry could be overlayed on the post-operative imaging studies.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Pre and postop Measurement Testing: Thirty-three interbody devices in 21 patients had pre-operative planning, simulation of cage dimensions to determine the proper cage fit which would provide for the desired correction of foraminal height and sagittal balance parameters. The simulated preoperative plan overlayed the final post-operative radiograph and was a near-perfect match in 20 of 21 patients (95.2%). Multiple Observers Measurement Testing: A Pearson product-moment correlation was run between each individual's pre-op and post-op middle column measurements. There was a strong, positive correlation between pre-operative and post-operative measurements, which was statistically significant (r = 0.903, n = 33, P < 0.001).
520 ## - SUMMARY, ETC.
Abstract STUDY DESIGN: This is a retrospective cohort study.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN PROCESS -- NOT YET INDEXED
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Sports Medicine
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Union Memorial Hospital
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Brooks, Daina M
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Cunningham, Bryan W
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Eisermann, Lukas
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors McAfee, Paul C
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Mullinex, Ken
790 ## - Authors
All authors Brooks DM, Cunningham BW, Eisermann L, McAfee PC, Mullinex K
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1177/21925682211003554">https://dx.doi.org/10.1177/21925682211003554</a>
Public note https://dx.doi.org/10.1177/21925682211003554
858 ## - ORCID
ORCID text Eisermann, Lukas
-- McAfee, Paul C
Orcid <a href="https://orcid.org/0000-0002-8959-5922">https://orcid.org/0000-0002-8959-5922</a>
-- <a href="https://orcid.org/0000-0002-3033-5464">https://orcid.org/0000-0002-3033-5464</a>
Name https://orcid.org/0000-0002-8959-5922
-- https://orcid.org/0000-0002-3033-5464
-- https://orcid.org/0000-0002-8959-5922
-- https://orcid.org/0000-0002-3033-5464
858 ## - ORCID
ORCID text Eisermann, Lukas
-- McAfee, Paul C
Orcid <a href="https://orcid.org/0000-0002-8959-5922">https://orcid.org/0000-0002-8959-5922</a>
-- <a href="https://orcid.org/0000-0002-3033-5464">https://orcid.org/0000-0002-3033-5464</a>
Name https://orcid.org/0000-0002-8959-5922
-- https://orcid.org/0000-0002-3033-5464
-- https://orcid.org/0000-0002-8959-5922
-- https://orcid.org/0000-0002-3033-5464
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 05/11/2022   35393879 35393879 05/11/2022 05/11/2022 Journal Article

Powered by Koha