MARC details
000 -LEADER |
fixed length control field |
03956nam a22004937a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
141111s20142014 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0002-9343 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
24608018 |
245 ## - TITLE STATEMENT |
Title |
Percutaneous aortic balloon valvotomy in the United States: a 13-year perspective. |
251 ## - Source |
Source |
American Journal of Medicine. 127(8):744-753.e3, 2014 Aug. |
252 ## - Abbreviated Source |
Abbreviated source |
Am J Med. 127(8):744-753.e3, 2014 Aug. |
253 ## - Journal Name |
Journal name |
The American journal of medicine |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2014 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2015 |
266 ## - Date added to catalog |
Date added to catalog |
2014-11-11 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1995 - present, Available in print through MWHC library: 1999 - present |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: We determined the contemporary trends of percutaneous aortic balloon valvotomy and its outcomes using the nation's largest hospitalization database. There has been a resurgence in the use of percutaneous aortic balloon valvotomy in patients at high surgical risk because of the development of less-invasive endovascular therapies. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: This study comprehensively evaluates trends for percutaneous aortic balloon valvotomy in the United States and demonstrates the significance of operator and hospital volume on outcomes. Copyright 2014 Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: This is a cross-sectional study with time trends using the Nationwide Inpatient Sample database between the years 1998 and 2010. We identified patients using the International Classification of Diseases, 9th Revision, Clinical Modification procedure code for valvotomy. Only patients aged more than 60 years with aortic stenosis were included. Primary outcome included in-hospital mortality, and secondary outcomes included procedural complications and length of hospital stay. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: A total of 2127 percutaneous aortic balloon valvotomies (weighted n = 10,640) were analyzed. The use rate of percutaneous aortic balloon valvotomy increased by 158% from 12 percutaneous aortic balloon valvotomies per million elderly patients in 1998-1999 to 31 percutaneous aortic balloon valvotomies per million elderly patients in 2009-2010 in the United States (P < .001). The hospital mortality decreased by 23% from 11.5% in 1998-1999 to 8.8% in 2009-2010 (P < .001). Significant predictors of in-hospital mortality were the presence of increasing comorbidities (P = .03), unstable patient (P < .001), any complication (P < .001), and weekend admission (P = .008), whereas increasing operator volume was associated with significantly reduced mortality (P = .03). Patients who were admitted to hospitals with the highest procedure volume and the highest volume operators had a 51% reduced likelihood (P = .05) of in-hospital mortality when compared with those in hospitals with the lowest procedure volume and lowest volume operators. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Balloon Valvuloplasty/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Heart Valve Diseases/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Percutaneous Coronary Intervention/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Balloon Valvuloplasty/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Odds Ratio |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Percutaneous Coronary Intervention/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Time Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
United States |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Washington Hospital Center |
656 ## - INDEX TERM--OCCUPATION |
Department |
Medicine/General Internal Medicine |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Chothani, Ankit |
790 ## - Authors |
All authors |
Arora S, Badheka AO, Chothani A, Cohen MG, De Marchena E, Desai H, Deshmukh A, Ghatak A, Grines CL, Grover P, Makkar R, Mehta K, O'Neill WW, Patel N, Patel NJ, Rathod A, Rihal CS, Savani GT, Schreiber T, Shah N, Singh V |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="http://dx.doi.org/10.1016/j.amjmed.2014.02.025">http://dx.doi.org/10.1016/j.amjmed.2014.02.025</a> |
Public note |
http://dx.doi.org/10.1016/j.amjmed.2014.02.025 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |