Explant vs Redo-TAVR After Transcatheter Valve Failure: Mid-Term Outcomes From the EXPLANTORREDO-TAVR International Registry. (Record no. 11890)

MARC details
000 -LEADER
fixed length control field 04785nam a22005897a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230601s20232023 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1936-8798
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.jcin.2023.01.376 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S1936-8798(23)00453-3 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 37100556
245 ## - TITLE STATEMENT
Title Explant vs Redo-TAVR After Transcatheter Valve Failure: Mid-Term Outcomes From the EXPLANTORREDO-TAVR International Registry.
251 ## - Source
Source Jacc: Cardiovascular Interventions. 16(8):927-941, 2023 04 24.
252 ## - Abbreviated Source
Abbreviated source JACC Cardiovasc Interv. 16(8):927-941, 2023 04 24.
253 ## - Journal Name
Journal name JACC. Cardiovascular interventions
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2023 04 24
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Medline status MEDLINE
266 ## - Date added to catalog
Date added to catalog 06/01/2023
501 ## - WITH NOTE
Local holdings Available online through MWHC library: 2008 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Valve reintervention after transcatheter aortic valve replacement (TAVR) failure has not been studied in detail.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: In this first report of the EXPLANTORREDO-TAVR global registry, TAVR-explant had a shorter median time to reintervention, with less structural valve degeneration, more prosthesis-patient mismatch, and similar paravalvular leak rates compared with redo-TAVR. TAVR-explant had higher mortality at 30 days and 1 year, but similar rates on landmark analysis after 30 days. Copyright © 2023 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: From May 2009 to February 2022, 396 patients in the international EXPLANTORREDO-TAVR registry underwent TAVR-explant (181, 46.4%) or redo-TAVR (215, 54.3%) for transcatheter heart valve (THV) failure during a separate admission from the initial TAVR. Outcomes were reported at 30 days and 1 year.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: The authors sought to determine outcomes of TAVR surgical explantation (TAVR-explant) vs redo-TAVR because they are largely unknown.
520 ## - SUMMARY, ETC.
Abstract RESULTS: The incidence of reintervention after THV failure was 0.59% with increasing volume during the study period. Median time from index-TAVR to reintervention was shorter in TAVR-explant vs redo-TAVR (17.6 months [IQR: 5.0-40.7 months] vs 45.7 months [IQR: 10.6-75.6 months]; P < 0.001], respectively. TAVR-explant had more prosthesis-patient mismatch (17.1% vs 0.5%; P < 0.001) as the indication for reintervention, whereas redo-TAVR had more structural valve degeneration (63.7% vs 51.9%; P = 0.023), with a similar incidence of >=moderate paravalvular leak between groups (28.7% vs 32.8% in redo-TAVR; P = 0.44). There was a similar proportion of balloon-expandable THV failures (39.8% TAVR-explant vs 40.5% redo-TAVR; P = 0.92). Median follow-up was 11.3 (IQR: 1.6-27.1 months) after reintervention. Compared with redo-TAVR, TAVR-explant had higher mortality at 30 days (13.6% vs 3.4%; P < 0.001) and 1 year (32.4% vs 15.4%; P = 0.001), with similar stroke rates between groups. On landmark analysis, mortality was similar between groups after 30 days (P = 0.91).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve Stenosis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Heart Valve Prosthesis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Heart Valve Prosthesis Implantation
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Transcatheter Aortic Valve Replacement
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prosthesis Design
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Registries
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Risk Factors
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Treatment Outcome
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Indexing Automated
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
657 ## - INDEX TERM--FUNCTION
Medline publication type Research Support, Non-U.S. Gov't
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Schults, Christian C
Institution Code MHVI
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Waksman, Ron
Institution Code MHVI
790 ## - Authors
All authors Abdel-Wahab M, Adrichem R, Ahmad H, Andreas M, Asgar AW, Bapat VN, Belluschi I, Ben-Ali W, Bhadra O, Cheung A, Colli A, Conradi L, Corona S, De Backer O, Denti P, Desai ND, Di Eusanio M, DiMaio JM, Forrest JK, Fukuhara S, Geirsson A, Goel SS, Goldberg JB, Grubb KJ, Hagl C, Herrmann HC, Hokken TW, Kaneko T, Kempfert J, Kiefer P, Kleiman NS, Kliger CA, Leon MB, Mach M, Mack MJ, Marin-Cuartas M, Meier D, Modine T, Nazif TN, Petrossian G, Pirelli L, Ramlawi B, Reardon MJ, Robinson N, Rovin JD, Ruge H, Saha S, Sathananthan J, Schults CC, Shih E, Sondergaard L, Szerlip M, Tang GHL, Taramasso M, Unbehaun A, Van Mieghem N, Vitanova K, Waksman R, Wang L, Webb JG, Wyler von Ballmoos M, Zaid S
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.jcin.2023.01.376">https://dx.doi.org/10.1016/j.jcin.2023.01.376</a>
Public note https://dx.doi.org/10.1016/j.jcin.2023.01.376
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 06/02/2023   37100556 37100556 06/02/2023 06/02/2023 Journal Article

Powered by Koha