Duration of balloon inflation for optimal stent deployment: five seconds is not enough. (Record no. 11962)

MARC details
000 -LEADER
fixed length control field 03528nam a22005177a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130912s20132013 xxu||||| |||| 00| 0 eng dOvid Technologies
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1522-1946
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 22109977
245 ## - TITLE STATEMENT
Title Duration of balloon inflation for optimal stent deployment: five seconds is not enough.
251 ## - Source
Source Catheterization & Cardiovascular Interventions. 81(3):446-53, 2013 Feb.
252 ## - Abbreviated Source
Abbreviated source Catheter Cardiovasc Interv. 81(3):446-53, 2013 Feb.
253 ## - Journal Name
Journal name Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
266 ## - Date added to catalog
Date added to catalog 2013-09-17
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 1996 - present, Available in print through MWHC library: 1996 - 2006
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Optimal stent expansion and apposition to the vessel wall are of critical importance to optimize the results of percutaneous coronary intervention (PCI). However, it is not known if stent inflation duration impacts on stent expansion.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: The duration of stent balloon inflation has a significant impact on stent expansion. Stent deployment for >25 sec is recommended. Copyright 2012 Wiley Periodicals, Inc.
520 ## - SUMMARY, ETC.
Abstract METHODS: We performed a prospective cohort study in patients undergoing PCI. Quantitative coronary angiography and DSE data were analyzed. DSE was performed at 5, 15, and 25 sec during stent implantation, after target balloon inflation pressure was achieved.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: To assess the effect of the duration of stent inflation on stent expansion using digital stent enhancement (DSE).
520 ## - SUMMARY, ETC.
Abstract RESULTS: One hundred and four consecutive patients (150 lesions) were enrolled. The mean age was 66.9 +/- 11.1 years. Complex lesions (ACC/AHA B2/C) occurred in 26.9%. Stents used: Cypher Select (54.1%), Xience V (30.6%), and Taxus Liberte (15.3%). The minimal stent diameter increased significantly with the duration of stent inflation: 2.60 +/- 0.51, 2.76 +/- 0.51, and 2.82 +/- 0.52 mm at 5, 15, and 25 sec (P < 0.0001). Similarly, maximal stent diameter increased with the duration of stent inflation: 3.21 +/- 0.51, 3.32 +/- 0.52, and 3.36 +/- 0.54 mm (P < 0.0001). The average stent diameter also increased with longer stent inflation (P < 0.0001). Using MUSIC criteria 24.0, 53.3, and 68.0% of stents were appropriately expanded at 5, 15, and 25 sec (P < 0.0001).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Angioplasty, Balloon, Coronary/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Coronary Angiography/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Coronary Stenosis/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Image Processing, Computer-Assisted/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Ultrasonography, Interventional/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aged
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Coronary Stenosis/ra [Radiography]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Coronary Stenosis/us [Ultrasonography]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Female
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Follow-Up Studies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Male
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Operative Time
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prospective Studies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Reproducibility of Results
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Stents
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Comparative Study
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
657 ## - INDEX TERM--FUNCTION
Medline publication type Research Support, Non-U.S. Gov't
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Pichard, Augusto D
790 ## - Authors
All authors Chevalier B, Garot P, Hovasse T, Lefevre T, Morice MC, Mylotte D, Pichard A, Salvatella N
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="http://dx.doi.org/10.1002/ccd.23343">http://dx.doi.org/10.1002/ccd.23343</a>
Public note http://dx.doi.org/10.1002/ccd.23343
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Journal article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 09/17/2013   22109977 09/17/2013 09/17/2013 Journal Article

Powered by Koha