MARC details
000 -LEADER |
fixed length control field |
03528nam a22005177a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
130912s20132013 xxu||||| |||| 00| 0 eng dOvid Technologies |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1522-1946 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
22109977 |
245 ## - TITLE STATEMENT |
Title |
Duration of balloon inflation for optimal stent deployment: five seconds is not enough. |
251 ## - Source |
Source |
Catheterization & Cardiovascular Interventions. 81(3):446-53, 2013 Feb. |
252 ## - Abbreviated Source |
Abbreviated source |
Catheter Cardiovasc Interv. 81(3):446-53, 2013 Feb. |
253 ## - Journal Name |
Journal name |
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions |
266 ## - Date added to catalog |
Date added to catalog |
2013-09-17 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1996 - present, Available in print through MWHC library: 1996 - 2006 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Optimal stent expansion and apposition to the vessel wall are of critical importance to optimize the results of percutaneous coronary intervention (PCI). However, it is not known if stent inflation duration impacts on stent expansion. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: The duration of stent balloon inflation has a significant impact on stent expansion. Stent deployment for >25 sec is recommended. Copyright 2012 Wiley Periodicals, Inc. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: We performed a prospective cohort study in patients undergoing PCI. Quantitative coronary angiography and DSE data were analyzed. DSE was performed at 5, 15, and 25 sec during stent implantation, after target balloon inflation pressure was achieved. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: To assess the effect of the duration of stent inflation on stent expansion using digital stent enhancement (DSE). |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: One hundred and four consecutive patients (150 lesions) were enrolled. The mean age was 66.9 +/- 11.1 years. Complex lesions (ACC/AHA B2/C) occurred in 26.9%. Stents used: Cypher Select (54.1%), Xience V (30.6%), and Taxus Liberte (15.3%). The minimal stent diameter increased significantly with the duration of stent inflation: 2.60 +/- 0.51, 2.76 +/- 0.51, and 2.82 +/- 0.52 mm at 5, 15, and 25 sec (P < 0.0001). Similarly, maximal stent diameter increased with the duration of stent inflation: 3.21 +/- 0.51, 3.32 +/- 0.52, and 3.36 +/- 0.54 mm (P < 0.0001). The average stent diameter also increased with longer stent inflation (P < 0.0001). Using MUSIC criteria 24.0, 53.3, and 68.0% of stents were appropriately expanded at 5, 15, and 25 sec (P < 0.0001). |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Angioplasty, Balloon, Coronary/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Coronary Angiography/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Coronary Stenosis/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Image Processing, Computer-Assisted/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Ultrasonography, Interventional/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Coronary Stenosis/ra [Radiography] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Coronary Stenosis/us [Ultrasonography] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Follow-Up Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Operative Time |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prospective Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Reproducibility of Results |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Stents |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Comparative Study |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Research Support, Non-U.S. Gov't |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Pichard, Augusto D |
790 ## - Authors |
All authors |
Chevalier B, Garot P, Hovasse T, Lefevre T, Morice MC, Mylotte D, Pichard A, Salvatella N |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="http://dx.doi.org/10.1002/ccd.23343">http://dx.doi.org/10.1002/ccd.23343</a> |
Public note |
http://dx.doi.org/10.1002/ccd.23343 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Journal article |