MARC details
000 -LEADER |
fixed length control field |
03434nam a22004817a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150429s20142014 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0720-048X |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
24873832 |
245 ## - TITLE STATEMENT |
Title |
Iterative model reconstruction: improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT. |
251 ## - Source |
Source |
European Journal of Radiology. 83(8):1408-15, 2014 Aug. |
252 ## - Abbreviated Source |
Abbreviated source |
Eur J Radiol. 83(8):1408-15, 2014 Aug. |
253 ## - Journal Name |
Journal name |
European journal of radiology |
266 ## - Date added to catalog |
Date added to catalog |
2015-04-29 |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: M-IR can provide significantly improved qualitative and quantitative image quality in prospectively gated coronary CTA using a low-tube-voltage.Copyright � 2014 Elsevier Ireland Ltd. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Thirty patients (16 men, 14 women; mean age 52.2 +/- 13.2 years) underwent coronary CTA at 100-kVp on a 256-slice CT. Paired image sets were created using 3 types of reconstruction, i.e. filtered back projection (FBP), a hybrid type of iterative reconstruction (H-IR), and M-IR. Quantitative parameters including CT-attenuation, image noise, and contrast-to-noise ratio (CNR) were measured. The visual image quality, i.e. graininess, beam-hardening, vessel sharpness, and overall image quality, was scored on a 5-point scale. Lastly, coronary artery segments were evaluated using a 4-point scale to investigate the assessability of each segment. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: To investigate the effects of a new model-based type of iterative reconstruction (M-IR) technique, the iterative model reconstruction, on image quality of prospectively gated coronary CT angiography (CTA) acquired at low-tube-voltage. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: There was no significant difference in coronary arterial CT attenuation among the 3 reconstruction methods. The mean image noise of FBP, H-IR, and M-IR images was 29.3 +/- 9.6, 19.3 +/- 6.9, and 12.9 +/- 3.3 HU, respectively, there were significant differences for all comparison combinations among the 3 methods (p<0.01). The CNR of M-IR was significantly better than of FBP and H-IR images (13.5 +/- 5.0 [FBP], 20.9 +/- 8.9 [H-IR] and 39.3 +/- 13.9 [M-IR]; p<0.01). The visual scores were significantly higher for M-IR than the other images (p<0.01), and 95.3% of the coronary segments imaged with M-IR were of assessable quality compared with 76.7% of FBP- and 86.9% of H-IR images. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Cardiac-Gated Imaging Techniques/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Coronary Angiography/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Radiographic Image Interpretation, Computer-Assisted/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Tomography, X-Ray Computed/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Adult |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Contrast Media/du [Diagnostic Use] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Iohexol/du [Diagnostic Use] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Middle Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Quality Improvement |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Retrospective Studies |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Oda, Seitaro |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Weigold, William Guy |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Weissman, Gaby |
790 ## - Authors |
All authors |
Oda S, Vembar M, Weigold WG, Weissman G |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="http://dx.doi.org/10.1016/j.ejrad.2014.04.027">http://dx.doi.org/10.1016/j.ejrad.2014.04.027</a> |
Public note |
http://dx.doi.org/10.1016/j.ejrad.2014.04.027 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Journal article |