Safety and performance of the third-generation drug-eluting resorbable coronary magnesium scaffold system in the treatment of subjects with de novo coronary artery lesions: 6-month results of the prospective, multicenter BIOMAG-I first-in-human study. (Record no. 12576)

MARC details
000 -LEADER
fixed length control field 03537nam a22004097a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230626s20232023 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 2589-5370
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.eclinm.2023.101940 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code PMC10126775 [pmc]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S2589-5370(23)00117-7 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 37113674
245 ## - TITLE STATEMENT
Title Safety and performance of the third-generation drug-eluting resorbable coronary magnesium scaffold system in the treatment of subjects with de novo coronary artery lesions: 6-month results of the prospective, multicenter BIOMAG-I first-in-human study.
251 ## - Source
Source EClinicalMedicine. 59:101940, 2023 May.
252 ## - Abbreviated Source
Abbreviated source EClinicalMedicine. 59:101940, 2023 May.
253 ## - Journal Name
Journal name EClinicalMedicine
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2023 May
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status epublish
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Medline status PubMed-not-MEDLINE
266 ## - Date added to catalog
Date added to catalog 2023-06-26
520 ## - SUMMARY, ETC.
Abstract Background: A third-generation coronary drug-eluting resorbable magnesium scaffold (DREAMS 3G) was developed to enhance the performance of previous scaffold generations and achieve angiographic outcomes comparable to those of contemporary drug-eluting stents.
520 ## - SUMMARY, ETC.
Abstract Findings: Between April 2020 and February 2022, 116 patients with 117 coronary artery lesions were enrolled. At six months, in-scaffold late lumen loss was 0.21 mm (SD 0.31). Intravascular ultrasound assessment showed preservation of the scaffold area (mean 7.59 mm2 [SD 2.21] post-procedure vs 6.96 mm2 [SD 2.48]) at six months) with a low mean neointimal area (0.02 mm2 [SD 0.10]). Optical coherence tomography revealed that struts were embedded in the vessel wall and were already hardly discernible at six months. Target lesion failure occurred in one (0.9%) patient; a clinically driven target lesion revascularization was performed on post-procedure day 166. No definite or probable scaffold thrombosis or myocardial infarction was observed.
520 ## - SUMMARY, ETC.
Abstract Funding: This study was funded by BIOTRONIK AG. Copyright © 2023 The Author(s).
520 ## - SUMMARY, ETC.
Abstract Interpretation: These findings show that the implantation of DREAMS 3G in de novo coronary lesions is associated with favorable safety and performance outcomes, comparable to contemporary drug-eluting stents.
520 ## - SUMMARY, ETC.
Abstract Methods: This prospective, multicenter, non-randomized, first-in-human study was conducted at 14 centers in Europe. Eligible patients had stable or unstable angina, documented silent ischemia, or non-ST-elevation myocardial infarction, and a maximum of two single de novo lesions in two separate coronary arteries with a reference vessel diameter between 2.5 mm and 4.2 mm. Clinical follow-up was scheduled at one, six and 12 months and annually thereafter until five years. Invasive imaging assessments were scheduled six and 12 months postoperatively. The primary endpoint was angiographic in-scaffold late lumen loss at six months. This trial was registered at ClinicalTrials.gov (NCT04157153).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Indexing Automated
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Garcia-Garcia, Hector M
Institution Code MHVI
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Waksman, Ron
Institution Code MHVI
790 ## - Authors
All authors Haude M, Wlodarczak A, van der Schaaf RJ, Torzewski J, Ferdinande B, Escaned J, Iglesias JF, Bennett J, Toth G, Joner M, Toelg R, Wiemer M, Olivecrona G, Vermeersch P, Garcia-Garcia HM, Waksman R
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.eclinm.2023.101940">https://dx.doi.org/10.1016/j.eclinm.2023.101940</a>
Public note https://dx.doi.org/10.1016/j.eclinm.2023.101940
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 06/26/2023   37113674 37113674 06/26/2023 06/26/2023 Journal Article

Powered by Koha