MARC details
000 -LEADER |
fixed length control field |
03789nam a22005297a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
230727s20232023 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1936-8798 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.jcin.2023.05.013 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S1936-8798(23)00834-8 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
37380228 |
245 ## - TITLE STATEMENT |
Title |
Real-World Outcomes of Fourth-Generation Mitral Transcatheter Repair: 30-Day Results From EXPAND G4. |
251 ## - Source |
Source |
Jacc: Cardiovascular Interventions. 16(12):1463-1473, 2023 06 26. |
252 ## - Abbreviated Source |
Abbreviated source |
JACC Cardiovasc Interv. 16(12):1463-1473, 2023 06 26. |
253 ## - Journal Name |
Journal name |
JACC. Cardiovascular interventions |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2023 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2023 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2023 06 26 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Medline status |
MEDLINE |
266 ## - Date added to catalog |
Date added to catalog |
2023-07-27 |
501 ## - WITH NOTE |
Local holdings |
Available online through MWHC library: 2008 - present |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting. Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 +/- 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR <= 2+, and 91% achieved MR <= 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Cardiomyopathies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Mitral Valve Insufficiency |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Echocardiography |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Mitral Valve Insufficiency/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Mitral Valve Insufficiency/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prospective Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Quality of Life |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Treatment Outcome |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Indexing |
Automated |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Health Research Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Multicenter Study |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Research Support, Non-U.S. Gov't |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Asch, Federico M |
Institution Code |
MHRI |
790 ## - Authors |
All authors |
Asch FM, Chehab B, De Marco F, Denti P, Mahoney P, Maisano F, Price MJ, Rinaldi M, Rodriguez E, Rogers JH, Rollefson WA, von Bardeleben RS, Williams MR |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.jcin.2023.05.013">https://dx.doi.org/10.1016/j.jcin.2023.05.013</a> |
Public note |
https://dx.doi.org/10.1016/j.jcin.2023.05.013 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |