Real-World Outcomes of Fourth-Generation Mitral Transcatheter Repair: 30-Day Results From EXPAND G4. (Record no. 12969)

MARC details
000 -LEADER
fixed length control field 03789nam a22005297a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230727s20232023 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1936-8798
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.jcin.2023.05.013 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S1936-8798(23)00834-8 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 37380228
245 ## - TITLE STATEMENT
Title Real-World Outcomes of Fourth-Generation Mitral Transcatheter Repair: 30-Day Results From EXPAND G4.
251 ## - Source
Source Jacc: Cardiovascular Interventions. 16(12):1463-1473, 2023 06 26.
252 ## - Abbreviated Source
Abbreviated source JACC Cardiovasc Interv. 16(12):1463-1473, 2023 06 26.
253 ## - Journal Name
Journal name JACC. Cardiovascular interventions
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2023
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2023 06 26
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Medline status MEDLINE
266 ## - Date added to catalog
Date added to catalog 2023-07-27
501 ## - WITH NOTE
Local holdings Available online through MWHC library: 2008 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting. Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting.
520 ## - SUMMARY, ETC.
Abstract RESULTS: In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 +/- 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR <= 2+, and 91% achieved MR <= 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Cardiomyopathies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Mitral Valve Insufficiency
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Echocardiography
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Mitral Valve Insufficiency/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Mitral Valve Insufficiency/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prospective Studies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Quality of Life
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Treatment Outcome
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Indexing Automated
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Health Research Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
657 ## - INDEX TERM--FUNCTION
Medline publication type Multicenter Study
657 ## - INDEX TERM--FUNCTION
Medline publication type Research Support, Non-U.S. Gov't
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Asch, Federico M
Institution Code MHRI
790 ## - Authors
All authors Asch FM, Chehab B, De Marco F, Denti P, Mahoney P, Maisano F, Price MJ, Rinaldi M, Rodriguez E, Rogers JH, Rollefson WA, von Bardeleben RS, Williams MR
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.jcin.2023.05.013">https://dx.doi.org/10.1016/j.jcin.2023.05.013</a>
Public note https://dx.doi.org/10.1016/j.jcin.2023.05.013
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 07/27/2023   37380228 37380228 07/27/2023 07/27/2023 Journal Article

Powered by Koha